Siemens FastLink

FastLink is a family of devices forming a (primarily) PDH transport network technology by Siemens. It serves the following functionalities:
  • transport of (leased) digital subscriber lines (typically 2 Mbps) over copper (1-pair G.SHDSL, 2-pair HDSL) and fiber (UG2 or proprietary single-fiber bi-directional system)
  • add/drop multiplex of digital subscriber lines, e.g. from E1 (2 Mbps) to E3 (34 Mbps)
  • optionally, add/drop multiplex up to STM-1 (electrical or optical)
  • optionally, subscriber line termination of (leased or switched) POTS + ISDN lines (V5_Access_Multiplexers)
  • optionally, cross-connect functionality

FastLink would typically be deployed as a transport network by a telecom operator around the year 2000. They would deploy a number of multiplexers at various points of presence, from where they would run HDSL, HSDSL or optical lines to the respective customers that subscribed to a variety of digital services. Between the points of presence there would typically be a ring, either at the E3 or (probably more often) at the STM-1 level within the digital hierarchy.

Component Carriers

Type Part Description
AMXLS Access Multiplexer Shelf
CMXII Cross-connect multiplexer II
OMX16S S42023-A841-xx Optical Multiplexer OMX16 Shelf
OMXLS S42023-A859-xx Optical Multiplexer OMX16 Shelf
SMXLS Synchronous Multiplexer SMX (STM-1/STM-4) Shelf
UMX2S AMXC Shelf (AMX + Concentration)
UMXLS Feeder Shelf

Components / Modules

Type Description Usable in component carrier
LTCOH HDSL (RTR/TM-03036, Tab 4, 1,168 Mbit/s, 2 pairs) OMX2S2, OMX16S
LT12CM HDSL (ETR 152 1,168 MBit/s, 2 pairs) OMX2S2, OMX16S
LT22CM HDSL (ETR 152,1,168 MBit/s, 2 pairs), dual OMX2S2
RPSII Remote Power Supply II OMXS2
LTO-LT, LTO-NT Optical (8,704 Mbit/s, SM, single fiber) OMXS2, OMX16S
LUC G.703 long-haul
LUCP G.703 long-haul with phantom power
LUCT UK2 according to FTZ 1 TR 221 with phantom power
LUOT-A Optical (2,048 Bit/s, two fibers)
OTSU2M Supervision OMXS2, UMXLS, OMX16S
SUE Supervision? UMXLS
OTRU36 Optical interface 36 Mbit/s (34Mbps F2an plus overhead) OMX16S
DXMX34 Multiplexer from 16x 2 Mbit/s to 34 Mbit/s
CUAII AMXS central processor AMXS
SUB162 Analog subscriber line card (16 port) AMXS
LLA102/104 Analog leased line AMXS
I8S0P ISDN line card (S0, 8 port) AMXS
IUL82 ISDN line card (Uk0 2B1Q, 8 port) AMXS
IUL84 ISDN line card (Uk0 3B4T, 8 port) AMXS

CPE (Customer Premises Equipment)

Type Description
NT12C 1x 2Mbit/1MBit (G.703)
Siemens_NT12CP 1x 2Mbit/1MBit G.703/G.704 or S2M (ISDN-PRA) over HDSL
Siemens_NT12CV 2x nx64k up to 2Mbit (V.35, V.36, X.21) over HDSL
NT22O 2x 2Mbit (G.703) optical
NT22OP 2x 2Mbit S2M (ISDN-PRA) optical
NT22OV 2x nx64k up to 2Mbit (V.35, V.36, X.21) optical
NTU 128k or 64k (V.35, V.36, X.21)
Siemens_ULAF+_STU

Auto-generated list of child pages

Files (1)
siemens_fastlink [2002].pdf View siemens_fastlink [2002].pdf 11.4 MB FastLink family product overview WIMPy, 03/20/2024 04:50 PM