Nokia EKSOS initial configuration

Prerequisites

Hardware: EKSOS shelf with power supply, 10Base-T ethernet connected to Q3 port and configuration PC, an NCU card and at least one line card
Software: EKSOS Node Manager software, running on Windows NT 4.0 (can be virtualized, ethernet port needs to be bridged to the VM)

Hardware reset to factory defaults

eksos_reset_jumper.jpg
It is recommended to start with a clean configuration on the node. To do this,
  1. remove power from the node
  2. pull the NCU card
  3. attach a horizontal jumper in the NR2K area, lower pins (pin 1 and 2, see picture above)
  4. reinstall the NCU card
  5. power up the node
  6. wait for the NCU (and Uk0 and LMU cards, if installed) to flash orange.
  7. wait for Uk0 and LMU cards, if installed, to flash green/yellow/red.
  8. remove power from the node, pull out NCU, remove jumper, reinstall NCU

Node Manager configuration

Initial configuration wizard

01_NM_FirstConnect.png
If you start up the NodeManager configuration software and ethernet is connected to the Q3 port of the NCU, you'll find an entry starting with "DEADDEAD". This is the factory default address. Select it and click "Manage".

02_NM_InitialDialog.png
This opens up the initial setup wizard. Click "Next".

03_NM_Description.png
Enter some details about your node.

04_NM_ChassisType.png
Select the correct chassis type (usually 17 slots).

05_NM_SysID.png
Select an area (there should be one already) and enter a 12 digit system identification.

06_NM_ChassisSlots.png
Now you can either configure module slots manually, or click "Configure from Node" for autodetection...

07_NM_Autodetection.png
...which might look like this if you only have a few cards inserted.

08_NM_DateTime.png
Update date and time from PC.

09_NM_InitialSummary.png
A summary of the initial configuration settings.

10_NM_InitialDisconnect.png
The wizards ends here with a disconnect from the node.

Connect to configured node

11_NM_RegularConnect.png
After some minutes, click "Connect to node" (first icon). The configured new system ID of your node should appear. Click "Manage".

12_NM_ChassisView.png

(work in progress)

Setup V5 interface for Osmo-V5

13_NM_NCUInterfaces.png 14_NM_NCUInterfaceConfig1.png 15_NM_NCUInterfaceConfig2.png 16_NM_NCUWriteConfig.png 17_NM_V5Config01.png 18_NM_V5Config02.png 19_NM_V5Config03.png 20_NM_V5Config04.png 21_NM_V5Config05.png 22_NM_V5Config06.png 23_NM_V5Config07.png 24_NM_V5Config08.png 25_NM_V5Config09.png 26_NM_V5Config10.png 27_NM_V5Config11.png 28_NM_V5Config12.png 29_NM_V5Config13.png 30_NM_V5Config14.png 31_NM_V5Config15.png

Configure PSTN interfaces

32_NM_PSTNConfig1.png 33_NM_PSTNConfig2.png 33_NM_PSTNConfig3.png 34_NM_PSTNConfig4.png 35_NM_PSTNConfig5.png 36_NM_PSTNConfig6.png

Configure ISDN interfaces

37_NM_ISDNConfig1.png 38_NM_ISDNConfig2.png 39_NM_ISDNConfig3.png 40_NM_ISDNConfig4.png

Configure PSTN/ISDN port/EF addresses

41_NM_IntUsage1.png 42_NM_IntUsage2.png 43_NM_IntUsage3.png 44_NM_IntUsage4.png 45_NM_IntUsage5.png 46_NM_IntUsage6.png 47_NM_IntUsage7.png 48_NM_IntUsage8.png 49_NM_IntUsage9.png

Enable V5 interface

50_NM_V5Enable1.png 51_NM_V5Enable2.png 52_NM_V5Enable3.png

Configure synchronisation

53_NM_Sync1.png 54_NM_Sync2.png

Save node configuration to file

55_NM_SaveConfig1.png 56_NM_SaveConfig2.png 57_NM_SaveConfig3.png 58_NM_Disconnect.png