nt2mku
- Login: nt2mku
- Copyright License:
- Registered on: 12/04/2023
- Last connection: 05/20/2024
Issues
open | closed | Total | |
---|---|---|---|
Assigned issues | 0 | 0 | 0 |
Reported issues | 2 | 0 | 2 |
Projects
Project | Roles | Registered on |
---|---|---|
Retronetworking | Contributor, Reporter | 12/08/2023 |
BBS-Revival | Contributor, Reporter | 12/08/2023 |
FidoNet | Contributor, Reporter | 12/08/2023 |
linmodem | Contributor, Reporter | 12/08/2023 |
UUCP and UseNet | Contributor, Reporter | 12/08/2023 |
Z-Netz | Contributor, Reporter | 12/08/2023 |
OCTOI - Osmocom Community TDM over IP | Contributor, Reporter | 12/08/2023 |
osmo-isdntap | Contributor, Reporter | 12/08/2023 |
Retro-GSM | Contributor, Reporter | 06/12/2024 |
Retrocomputing | Contributor, Reporter | 12/08/2023 |
Activity
05/22/2024
- 11:33 AM OsmoMSC Bug #6461: GSM 04.08 phase 1: Mobile terminated setup messages - octet 3a in case of speech
- Related: https://gerrit.osmocom.org/c/libosmocore/+/36784 - but the encoding should consider the MS specification pha...
- 10:23 AM OsmoMSC Bug #6461 (New): GSM 04.08 phase 1: Mobile terminated setup messages - octet 3a in case of speech
- Some early GSM phones implementing phase 1 specification (here: Siemens P1; S/W version 18.06.93 09:58:48) reject mob...
- 12:18 AM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
- laforge wrote in #note-10:
> I checked TS 05.05 4.23 and it already contains higher power control levels. So only ph...
05/21/2024
- 04:24 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
- ...and here is another document for DCS (which contains the ETSI STY files).
- 04:10 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
- Word 6.0 for WinNT runs fine on Win10.
- 01:49 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
- Thanks for moving the ticket. I did another test today generating trace files:
* PCAP of OsmoBTS-gsmtap and RSL
* Log...
05/20/2024
- 02:38 PM OsmoBSC Bug #6459: Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
- Sorry, wrong project category. It's for OsmoBSC, so please either delete or move to OsmoBSC. Thanks.
- 02:36 PM OsmoBSC Bug #6459 (New): Siemens P1 stops uplink transmission if MS power level is being set below 15 dBm
- This is more a documentation about a speciality of the Siemens P1 (Telekom D1 314) than a bug report.
* If setting...
05/02/2024
- 09:22 PM Retronetworking Wiki edit: Nokia_EKSOS_Initial_configuration (#9)
- 09:18 PM Retronetworking Wiki edit: Nokia_EKSOS_Initial_configuration (#8)
Also available in: Atom