Project

General

Profile

Actions

Nokia EKSOS Initial configuration » History » Revision 3

« Previous | Revision 3/9 (diff) | Next »
nt2mku, 05/02/2024 10:12 AM


Nokia EKSOS initial configuration

Prerequisites

Hardware: EKSOS shelf with power supply, 10Base-T ethernet connected to Q3 port and configuration PC, an NCU card and at least one line card
Software: EKSOS Node Manager software, running on Windows NT 4.0 (can be virtualized, ethernet port needs to be bridged to the VM)

Hardware reset to factory defaults

eksos_reset_jumper.jpg
It is recommended to start with a clean configuration on the node. To do this,
  1. remove power from the node
  2. pull the NCU card
  3. attach a horizontal jumper in the NR2K area, lower pins (pin 1 and 2, see picture above)
  4. reinstall the NCU card
  5. power up the node
  6. wait for the NCU (and Uk0 and LMU cards, if installed) to flash orange.
  7. wait for Uk0 and LMU cards, if installed, to flash green/yellow/red.
  8. remove power from the node, pull out NCU, remove jumper, reinstall NCU

NodeManager configuration

01_NM_FirstConnect.png
If you start up the NodeManager configuration software and ethernet is connected to the Q3 port of the NCU, you'll find an entry starting with "DEADDEAD". This is the factory default address. Select it and click "Manage".

02_NM_InitialDialog.png
This opens up the initial setup wizard. Click "Next".

03_NM_Description.png
Enter some details about your node.

04_NM_ChassisType.png
Select the correct chassis type (usually 17 slots).

05_NM_SysID.png
Select an area (there should be one already) and enter a 12 digit system identification.

06_NM_ChassisSlots.png
Now you can either configure module slots manually, or click "Configure from Node" for autodetection...

07_NM_Autodetection.png
...which might look like this if you only have a few cards inserted.

08_NM_DateTime.png
Update date and time from PC.

09_NM_InitialSummary.png
A summary of the initial configuration settings.

10_NM_InitialDisconnect.png
The wizards ends here with a disconnect from the node.

11_NM_RegularConnect.png
After some minutes, click "Connect to node" (first icon). The configured new system ID of your node should appear. Click "Manage".

12_NM_ChassisView.png

13_NM_NCUInterfaces.png 14_NM_NCUInterfaceConfig1.png 15_NM_NCUInterfaceConfig2.png 16_NM_NCUWriteConfig.png 17_NM_V5Config01.png 18_NM_V5Config02.png 19_NM_V5Config03.png 20_NM_V5Config04.png 21_NM_V5Config05.png

Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)
Error executing the thumbnail macro (Filename required)

(work in progress)

Updated by nt2mku 2 months ago · 3 revisions