h1. Nokia EKSOS initial configuration
2
3
h2. Prerequisites
4
5
Hardware: EKSOS shelf with power supply, 10Base-T ethernet connected to Q3 port and configuration PC, an NCU card and at least one line card
6
Software: EKSOS Node Manager software, running on Windows NT 4.0 (can be virtualized, ethernet port needs to be bridged to the VM)
7
8
h2. Hardware reset to factory defaults
9
10
{{thumbnail(eksos_reset_jumper.jpg)}}
11
It is recommended to start with a clean configuration on the node. To do this,
12
# remove power from the node
13
# pull the NCU card
14
# attach a horizontal jumper in the NR2K area, lower pins (pin 1 and 2, see picture above) 
15
# reinstall the NCU card
16
# power up the node
17
# wait for the NCU (and Uk0 and LMU cards, if installed) to flash orange. 
18
# wait for Uk0 and LMU cards, if installed, to flash green/yellow/red. 
19
# remove power from the node, pull out NCU, remove jumper, reinstall NCU
20
21 7 nt2mku
h2. Node Manager configuration
22 1 nt2mku
23 7 nt2mku
h3. Initial configuration wizard
24
25 1 nt2mku
{{thumbnail(01_NM_FirstConnect.png)}}
26
If you start up the NodeManager configuration software and ethernet is connected to the Q3 port of the NCU, you'll find an entry starting with "DEADDEAD". This is the factory default address. Select it and click "Manage".
27
28
{{thumbnail(02_NM_InitialDialog.png)}}
29
This opens up the initial setup wizard. Click "Next".
30
31
{{thumbnail(03_NM_Description.png)}}
32
Enter some details about your node.
33
34
{{thumbnail(04_NM_ChassisType.png)}}
35
Select the correct chassis type (usually 17 slots).
36
37
{{thumbnail(05_NM_SysID.png)}}
38 2 nt2mku
Select an area (there should be one already) and enter a 12 digit system identification.
39 1 nt2mku
40 2 nt2mku
{{thumbnail(06_NM_ChassisSlots.png)}}
41
Now you can either configure module slots manually, or click "Configure from Node" for autodetection...
42
43
{{thumbnail(07_NM_Autodetection.png)}}
44
...which might look like this if you only have a few cards inserted.
45
46
{{thumbnail(08_NM_DateTime.png)}}
47
Update date and time from PC.
48
49
{{thumbnail(09_NM_InitialSummary.png)}}
50
A summary of the initial configuration settings.
51
52
{{thumbnail(10_NM_InitialDisconnect.png)}}
53
The wizards ends here with a disconnect from the node.
54 1 nt2mku
55 7 nt2mku
h3. Connect to configured node
56
57 2 nt2mku
{{thumbnail(11_NM_RegularConnect.png)}}
58 8 nt2mku
After some minutes, click "Connect to node" (1st icon of top icon bar). The configured new system ID of your node should appear. Click "Manage".
59 3 nt2mku
60 1 nt2mku
{{thumbnail(12_NM_ChassisView.png)}}
61 8 nt2mku
This is the main view after connecting to a node. You can see the installed cards and its status.
62 7 nt2mku
63 1 nt2mku
h3. Setup V5 interface for Osmo-V5
64
65 7 nt2mku
{{thumbnail(13_NM_NCUInterfaces.png)}}
66 8 nt2mku
Now the connection to Osmo-V5 needs to be configured. Right-click the NCU card and select "Configure Interface".
67
68 7 nt2mku
{{thumbnail(14_NM_NCUInterfaceConfig1.png)}}
69 8 nt2mku
The 4 E1 interfaces of the NCU are shown. Right-click the first one and select "Configure".
70
71 3 nt2mku
{{thumbnail(15_NM_NCUInterfaceConfig2.png)}}
72 8 nt2mku
Tick "Interface in use" and optionally choose a name for the interface. Click "OK".
73
74 3 nt2mku
{{thumbnail(16_NM_NCUWriteConfig.png)}}
75 8 nt2mku
Click the third button "Send to Node" from the top button bar to write the changes to the node. This procedure is the same for other configuration windows if you have made any changes.
76
77 3 nt2mku
{{thumbnail(17_NM_V5Config01.png)}}
78 8 nt2mku
Now it's time for the V5 configuration. Click the 4th button from the right "Configure V5 Interface" of the top button bar.
79
80 3 nt2mku
{{thumbnail(18_NM_V5Config02.png)}}
81 8 nt2mku
Your interface list should be empty. Click "New V5.2".
82
83 3 nt2mku
{{thumbnail(19_NM_V5Config03.png)}}
84 8 nt2mku
The V5.2 wizard opens. Click "Next".
85
86 3 nt2mku
{{thumbnail(20_NM_V5Config04.png)}}
87 8 nt2mku
Enter an interface name and an interface ID (IFID) - there might be a sticker on the node front if you don't want to assign an individual IFID. Leave Provisioning variant to 0 and click "Advanced".
88
89 3 nt2mku
{{thumbnail(21_NM_V5Config05.png)}}
90 8 nt2mku
Tick "Disable Link Id Checking". Select "V1 Case 2" startup behaviour, 0 minutes delay, startup allowed during PSTN failure and accelerated unblocking. Click "OK" and "Next".
91
92 3 nt2mku
{{thumbnail(22_NM_V5Config06.png)}}
93 8 nt2mku
Select "U1 i/f: 1" and click "Add Link".
94
95 3 nt2mku
{{thumbnail(23_NM_V5Config07.png)}}
96 8 nt2mku
Leave all possible timeslots selected and click "OK", then "Next".
97
98 4 nt2mku
{{thumbnail(24_NM_V5Config08.png)}}
99 8 nt2mku
Select "TS 16" column of line "U1 i/f:1" and click "Add" to define a C-Channel.
100
101 4 nt2mku
{{thumbnail(25_NM_V5Config09.png)}}
102 8 nt2mku
Use C-Channel-ID 0 and click "OK".
103
104 4 nt2mku
{{thumbnail(26_NM_V5Config10.png)}}
105 8 nt2mku
Should look like this now. Click "Next".
106
107 1 nt2mku
{{thumbnail(27_NM_V5Config11.png)}}
108 8 nt2mku
Here are the definitions for signalling protocols of the C-Channel. Select "TS 16" column of line "U1 i/f:1" and click "Add" to bind protocols to the C-Channel.
109
110
111 4 nt2mku
{{thumbnail(28_NM_V5Config12.png)}}
112 8 nt2mku
Tick all signalling protocols (Vital, PSTN, ISDN-Ds, ISDN-p) and click "OK".
113
114 4 nt2mku
{{thumbnail(29_NM_V5Config13.png)}}
115 8 nt2mku
The signalling protocols should be displayed as shown above. There is a new option "PSTN mapping" now where you select country-specific PSTN protocol parameters. The mapping "United Kingdom" offers some additional PSTN line signals like polarity reversal or loop disconnect. Click "Finish".
116
117 4 nt2mku
{{thumbnail(30_NM_V5Config14.png)}}
118 8 nt2mku
A summary of the V5 interface configuration follows. Click "Create".
119
120 1 nt2mku
{{thumbnail(31_NM_V5Config15.png)}}
121 8 nt2mku
You should find the configured interface within the list. Leave it at state "Stopped" since some options are not available if the interface is in started state. Click "Send to node" if available and close the dialog.
122 1 nt2mku
123 8 nt2mku
124 1 nt2mku
h3. Configure PSTN interfaces
125
126
{{thumbnail(32_NM_PSTNConfig1.png)}}
127 8 nt2mku
A right-click on a PSTN line card offers the option "Configure Interface" to change line parameters of certain or all ports of that card.
128
129
130 7 nt2mku
{{thumbnail(33_NM_PSTNConfig2.png)}}
131 8 nt2mku
Right-click on the desired port and select "Configure".
132
133 1 nt2mku
{{thumbnail(33_NM_PSTNConfig3.png)}}
134 8 nt2mku
You can choose a name for that interface. If you operate a payphone on that line, consider the Feeding mode "Normal with optional current" to offer an increased line current for the phone.
135
136
137 5 nt2mku
{{thumbnail(34_NM_PSTNConfig4.png)}}
138 8 nt2mku
The "General" tab is of no interest since you can only select one value per setting.
139
140 5 nt2mku
{{thumbnail(35_NM_PSTNConfig5.png)}}
141 8 nt2mku
The "Speech" tab offers the possibility to modify input and output amplifications and line impedances.
142
143 5 nt2mku
{{thumbnail(36_NM_PSTNConfig6.png)}}
144 8 nt2mku
Modifications of one port can be pushed to other ports of the line card by selecting "Also Apply To".
145 7 nt2mku
146 1 nt2mku
h3. Configure ISDN interfaces
147
148 7 nt2mku
{{thumbnail(37_NM_ISDNConfig1.png)}}
149 8 nt2mku
Like shown with PSTN, ISDN ports of an interface card can be configured by right-click on the card and selecting "Configure Interface".
150
151 7 nt2mku
{{thumbnail(38_NM_ISDNConfig2.png)}}
152 8 nt2mku
Right-click the port you want to configure and select "Configure".
153
154 6 nt2mku
{{thumbnail(39_NM_ISDNConfig3.png)}}
155 8 nt2mku
Here you can assign a name to the port. If you tick "Monitored", link failures of that port will generate an alarm indicated by orange LED of the line card.
156
157 6 nt2mku
{{thumbnail(40_NM_ISDNConfig4.png)}}
158 8 nt2mku
Select a feeding voltage of -97V to supply NT1s. This setting applies to all ports of the line card.
159 7 nt2mku
160 1 nt2mku
h3. Configure PSTN/ISDN port/EF addresses
161
162 7 nt2mku
{{thumbnail(41_NM_IntUsage1.png)}}
163 8 nt2mku
A PSTN or ISDN port needs an individual address on the V5 side. The assignment of these addresses can be started by clicking the 3rd button from the right "Configure Interface Usage".
164
165 7 nt2mku
{{thumbnail(42_NM_IntUsage2.png)}}
166 8 nt2mku
Select tab "User Ports".
167
168 6 nt2mku
{{thumbnail(43_NM_IntUsage3.png)}}
169 8 nt2mku
Select filter "All units" / "All" to show all ports of the node.
170
171 3 nt2mku
{{thumbnail(44_NM_IntUsage4.png)}}
172 8 nt2mku
Here is an example assignment for a PSTN line card. Mark the first and the last port of the card (hold down shift) and click "Assign".
173
174 3 nt2mku
{{thumbnail(45_NM_IntUsage5.png)}}
175 8 nt2mku
A dialog opens for the first selected port. Choose a L3 address for that port - the other selected ports will be enumerated consecutively. A suggestion for the first port address of a line card is the slot number, multiplied by 100 (e.g. 300 for slot 3).
176
177 3 nt2mku
{{thumbnail(46_NM_IntUsage6.png)}}
178 8 nt2mku
The selected ports will now have an address assigned.
179
180 1 nt2mku
{{thumbnail(47_NM_IntUsage7.png)}}
181 8 nt2mku
Here is an assignment for an ISDN card. Mark all ports of that card and click "Assign".
182
183 1 nt2mku
{{thumbnail(48_NM_IntUsage8.png)}}
184 8 nt2mku
A dialog opens for the first selected port. Choose a L3 (EF) address for that port - the other selected ports will be enumerated consecutively. A suggestion for the first port address of a line card is the slot number, multiplied by 100 (e.g. 500 for slot 5).
185
Select Ds-type C-Channel ID = 0 and p-type C-Channel ID = <none>.
186
187 1 nt2mku
{{thumbnail(49_NM_IntUsage9.png)}}
188 8 nt2mku
If all addresses are assigned, send the configuration to the node (3rd button).
189 7 nt2mku
190 1 nt2mku
h3. Enable V5 interface
191
192 7 nt2mku
{{thumbnail(50_NM_V5Enable1.png)}}
193 8 nt2mku
Now it's time to start the V5 interface. Click "Configure V5 Interfaces" (4th button from right).
194
195 7 nt2mku
{{thumbnail(51_NM_V5Enable2.png)}}
196 8 nt2mku
Select the interface in the list and click "Start".
197
198 7 nt2mku
{{thumbnail(52_NM_V5Enable3.png)}}
199 8 nt2mku
After a few minutes, the interface should change the state to Enabled/Started, if Osmo-V5 is already configured correctly.
200 1 nt2mku
201
h3. Configure synchronisation
202
203 7 nt2mku
{{thumbnail(53_NM_Sync1.png)}}
204 8 nt2mku
The last item to configure is synchronisation. Click "Configure Synchronisation" (7th button from the right).
205
206 7 nt2mku
{{thumbnail(54_NM_Sync2.png)}}
207 8 nt2mku
Add the V5 interface by selecting "U1 2M i/f:1" from the lower list and clicking "Add". Click "Send to node" from the top bar.
208 7 nt2mku
209 1 nt2mku
h3. Save node configuration to file
210
211 7 nt2mku
{{thumbnail(55_NM_SaveConfig1.png)}}
212 8 nt2mku
To save your configuration to a file, click "Data" -> "Save to File".
213
214 7 nt2mku
{{thumbnail(56_NM_SaveConfig2.png)}}
215 8 nt2mku
Tick "Save All" and click "OK". Node configuration will be collected.
216
217 7 nt2mku
{{thumbnail(57_NM_SaveConfig3.png)}}
218 8 nt2mku
Save the configuration to a file.
219
220 7 nt2mku
{{thumbnail(58_NM_Disconnect.png)}}
221 8 nt2mku
If you've finished configuring the node, click "Stop Managing Node" (2nd button from left of top button bar).