Nokia EKSOS initial configuration

Prerequisites

Hardware: EKSOS shelf with power supply, 10Base-T ethernet connected to Q3 port and configuration PC, an NCU card and at least one line card
Software: EKSOS Node Manager software, running on Windows NT 4.0 (can be virtualized, ethernet port needs to be bridged to the VM)

Hardware reset to factory defaults

eksos_reset_jumper.jpg
It is recommended to start with a clean configuration on the node. To do this,
  1. remove power from the node
  2. pull the NCU card
  3. attach a horizontal jumper in the NR2K area, lower pins (pin 1 and 2, see picture above)
  4. reinstall the NCU card
  5. power up the node
  6. wait for the NCU (and Uk0 and LMU cards, if installed) to flash orange.
  7. wait for Uk0 and LMU cards, if installed, to flash green/yellow/red.
  8. remove power from the node, pull out NCU, remove jumper, reinstall NCU

NodeManager configuration

01_NM_FirstConnect.png
If you start up the NodeManager configuration software and ethernet is connected to the Q3 port of the NCU, you'll find an entry starting with "DEADDEAD". This is the factory default address. Select it and click "Manage".

02_NM_InitialDialog.png
This opens up the initial setup wizard. Click "Next".

03_NM_Description.png
Enter some details about your node.

04_NM_ChassisType.png
Select the correct chassis type (usually 17 slots).

05_NM_SysID.png
Select a database (there should be one already) and enter a 12 digit system identification.

(work in progress)

Updated by nt2mku 2 months ago · 1 revisions