Project

General

Profile

Actions

Bug #1622

closed

OsmoBTS power control incompliant to TS 05.08 and TS 08.58

Added by laforge about 8 years ago. Updated over 4 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
02/23/2016
Due date:
% Done:

100%

Spec Reference:

Description

The way how OsmoBTS interprets the A-bis RSL information elements regarding MS and BS power control is wrong.

For a description of the current behavior, see http://openbsc.osmocom.org/trac/wiki/GsmPowerControl

Furthermore, even the actual power control loop is completely simplistic, results in oscillations and doesn't implement any of the configurable averaging as specified in TS 05.08.

What needs to be done is:
correctly parse and interpret the various MS / BS power related IEs on RSL
implement Annex A of TS 05.08 (measurement averaging, MS power control)


Checklist

  • fix behavior on BSC side (always send MS power parameters in RSL CHAN ACT)
  • fix behavior on BTS side: autonomous UL power control ony if MS power parametrs IE was sent
  • TTCN3 tests for static MS power level in RSL CHAN ACT
  • TTCN3 tests for static MS power level in MS POWER CONTROL
  • TTCN3 test for autonomous MS power control after RSL CHAN ACT
  • TTCN3 test for autonomous MS power control after MS POWER CONTROL
  • Ensure the ms power level is actually interpreted as the maximum allowable power level if a ms power parameters IE is present

Related issues

Related to OsmoBTS - Feature #1851: generalize power control and TA loop codeResolvedpespin11/18/2016

Actions
Related to OsmoBTS - Feature #3750: Extension of BTS_Tests.ttcn test coverageResolved01/08/2019