Feature #1825
closeddecode OM2000 fault report
100%
Description
- internal fault map class 1a
- internal fault map class 1b
- internal fault map class 2a
- external condition map class 1
- external condition map class 2
- replacement unit map
- for each of the maps
- iterate over each byte from offset 0..n
- iterate over each bit from 0..7
- print "%s Fault %u:%u\n" (name_of_map, byte_nr, bit_nr)
- iterate over each bit from 0..7
- iterate over each byte from offset 0..n
If we receive a fault report with all bytes in all maps set to zero, we shoulr print "All faults ceased" at the same WARNING level.
Attaching a sample PCAP file with a TF FAULT REPORT
Files
Updated by dexter over 7 years ago
- % Done changed from 0 to 80
We now have some code that displays the fault maps in the following style:
Fault report: Internal Fault Map Class 1A (0,2,4,6)
Fault report: Internal Fault Map Class 1B (0,2,4,6)
Fault report: Internal Fault Map Class 2A (0,2,4,6,4,5)
Fault report: External Condition Map Class 1 (1)
Fault report: External Condition Map Class 2 (4)
The number in brackets is the bit number When all faults are ceased it displays:
Fault report: All faults ceased!
As soon as the BSC box works again I will insert the code in abis_om2000.c
Updated by dexter over 7 years ago
- % Done changed from 80 to 90
Code now integrated in abis_om2000.c, looks ok to me. However I do not have enough faults to be sure.
Updated by dexter over 7 years ago
- Status changed from In Progress to Resolved
- % Done changed from 90 to 100