The Hirschmann plug used for the power connection is called _Hirschmann Leitungsdose CA 4 LD 09 ZS_ and has the product number
6 1 laforge
932 362-100. The BS-11 includes one such plug, so unless you loose it, damage it or want multiple power cables, there is no need in obtaining this plug separately.
7 9 laforge
8
The pin-out is as follows:
9 17 laforge
* GND: your shealding/earth line (PE), German:yellow/green wire
10
* 1: phase (L), German: Brown wire
11
* 2: not connected
12
* 3: neutral (N), German: Blue wire
13 1 laforge
14 10 laforge
Please refer to the photograph of a fully wired plug:
15 1 laforge
[[Image(ps_plug.jpg, 25%, align=right)]]
16
17
18 17 laforge
h2. E1 Hardware interface
19
20
21 1 laforge
We are using a 120 Ohms balanced connection between the BS11 and a HFC-E1 card.
22
To configure the BS11 hardware correctly, you need to
23 17 laforge
* open the connection between pin 2 and 3 of the 4 jumpers below connector J01
24 3 laforge
25 1 laforge
26 17 laforge
h3. Cable to RJ45
27 1 laforge
28
29 17 laforge
The E1 interface[s] of the BS-11 are on some strange BNC-related twinax plugs called "BR2" (Radiall product # 605006000), you can find the PDF data sheet of the connectors at "Radiall":http://radiall.applixia.net/catalogue/resource?path=PRODUCT/PDF/TDS/coaxialconnectors/R605006000EN.pdf.  There are four such plugs included in the BS-11 package.  If  you need more, you can buy them online from "this link":http://webradiall.applixia.net/buyonline?PN=R605006000&LANG=en&SUP=FARNELL (which for Germany results in a hyperlink to "this page of the Farnell webshop":http://de.farnell.com/jsp/displayProduct.jsp?sku=4196995 where they cost EUR 16.51 each).
30 1 laforge
31 17 laforge
* left Y01 PCM in (from BSC): RJ45 pin 4,5
32
* Y02 PCM out (to BSC): RJ45 pin 1,2
33
* Y03 PCM left open
34
* Y04 PCM left open
35
36
[[E1-to-RJ45|Step-by-step guide]]
37
38 1 laforge
the polarity of the two wires (4,5) or (1,2) inside one twinax plug does not matter, as the signals are symmetric anyway.
39
40
41 17 laforge
h2. Firmware / Minimal Configuration
42
43
44 1 laforge
The BS-11 runs firmware.  The firmware consists of
45 17 laforge
* the SMU safety load (has to be loaded over RS232)
46
* the actual firmware images for the individual components inside the BS-11
47 1 laforge
48 17 laforge
Firmware can be installed using either the proprietary 16-bit windows program LMT, or the [[bs11_config]] program which is part
49
of [[OpenBSC]].
50 1 laforge
51
There is also a object database for the physical and functional objects inside the BTS.  The object database consist of a set of attributes (and their values) for each object. Most parts of this database are stored in non-volatile memory of the BTS.
52
53 17 laforge
the so-called *Minimal Configuration* consists of those objects and attributes that need to be configured over the RS232 link
54 1 laforge
before an A-bis over E1 connection can be made.  After the minimal configuration has been established, all other steps such as
55
software download and further configuration can be done over the E1 link.  The minimal configuration needs a valid SMU safety load
56
installed.
57
58 15 laforge
59 17 laforge
h3. bs11_config
60 15 laforge
61 17 laforge
62
Please see the [[bs11_config]] page.
63
64 15 laforge
The actual configuration of the objects is compiled-in.  You can only change it by changing the source code.
65 10 laforge
66 11 laforge
67 17 laforge
h3. LMT
68
69
70 11 laforge
If you're using LMT, you have to use the following procedure for firmware download and settings for the BTSM object:
71
72 17 laforge
* Start LMT Release 04.21(!) and make sure the cable is connected.
73
* Set the serial port to the port you connected your serial console
74 11 laforge
   cable to
75 17 laforge
* Logon as Administrator (Password is "admin")
76
* The factory configuration will not have any software installed
77 11 laforge
   (Phase will show Software required)
78 17 laforge
* Select Software->Download SM Safety Load to load BTSBMC76.SWI from
79 11 laforge
   the HS010876 directory
80 17 laforge
* After the download completes the BTS will restart and enter Phase
81 11 laforge
   Wait Min Config
82 17 laforge
* Create an Object "LI", "GPSU", "ALCO", "CCLK", "BBSIG 0", with the
83 11 laforge
   default config
84 17 laforge
* Create an Object "PA 0" with the following config: "GSM 0,03W(M3)"
85 11 laforge
   This point is important to reduce the antenna power output!
86 17 laforge
* You will need a special password to activate "BBSIG 1" and "PA 1"
87 11 laforge
   Configuration is analog to Channel 0
88 17 laforge
* Create Object "EnvaBTSE 0" up to "EnvaBTSE 3" with the default
89 11 laforge
   options
90 17 laforge
* As soon as all configuration options are set up the BTS will enter
91 1 laforge
   the Maintenance phase and you will be able to load the main firmware
92 17 laforge
* Select "Download SM" in and select the file HS011106.SWL from the
93 1 laforge
   HS011106 directory
94 17 laforge
* Grab a coffee and occupy yourself for about 45mins
95
* In BTSM Object set Timeslot no. to 1, Subslot no. to 64kbit/s
96 1 laforge
   signalling and TEI to 25