Project

General

Profile

Actions

BS11Configuration » History » Revision 10

« Previous | Revision 10/18 (diff) | Next »
laforge, 02/19/2016 10:47 PM
add link to


Power Connection

The Hirschmann plug used for the power connection is called ''Hirschmann Leitungsdose CA 4 LD 09 ZS'' and has the product number
932 362-100.

The pin-out is as follows: * GND: your shealding/earth line (PE), German:yellow/green wire * 1: phase (L), German: Brown wire * 2: not connected * 3: neutral (N), German: Blue wire

Please refer to the photograph of a fully wired plug:
Image(ps_plug.jpg, 25%, align=right)

E1 Hardware interface

We are using a 120 Ohms balanced connection between the BS11 and a HFC-E1 card.
To configure the BS11 hardware correctly, you need to * open the connection between pin 2 and 3 of the 4 jumpers below connector J01

=== Cable to RJ45 ===

The E1 interface[s] of the BS-11 are on some strange BNC-related twinax plugs called "BR2" (Radiall product # 605006000), you can find the PDF data sheet of the connectors at [http://radiall.applixia.net/catalogue/resource?path=PRODUCT/PDF/TDS/coaxialconnectors/R605006000EN.pdf Radiall] and you can buy them online from [http://webradiall.applixia.net/buyonline?PN=R605006000&LANG=en&SUP=FARNELL this link] (which for Germany results in a hyperlink to [http://de.farnell.com/jsp/displayProduct.jsp?sku=4196995 this page of the Farnell webshop] where they cost EUR 16.51 each).

  • left Y01 PCM in (from BSC): RJ45 pin 4,5
  • Y02 PCM out (to BSC): RJ45 pin 1,2
  • Y03 PCM left open
  • Y04 PCM left open
Configuration of BTSM Object

=== bs11_config ===

If you're using [wiki:bs11_config], then the configuration is compiled-in (thus automatically
correct) and you can only change it by changing the source code.

=== LMT ===

If you're using LMT, you have to use the following settings for the BTSM object:

  • BS11 requires PCM30CRC4 64kBit/s no Subslots
  • OM Layer on Timeslot 1
  • TEI for OM Layer default Siemens is 25 (but configurable in BS11 [wiki:LMT])
  • the following parameters are not configurable * RSL Layer on Timeslot 1, too * TEI for RSL is fixed in Siemens equipment * TEI = 0 für TRX0 * TEI = 1 für TRX1 * Attention: if you select OM Layer TEI 0 oder 1, RSL can no longer be brought up
  • Timeslots for TCHs * TRX0: TS2 und TS3 * TRX1: TS4 und TS5

=== E1 interface ===

LI Objekt: Line MULTIDROP

Impedance 120 Ohm balanced to connect to HFC-E1 board
Additionally you will need to change some jumpers on the connector board
of BS11: * dip-switch SW3: * 1-4: off * 5-8: on * TB01: no jumper * TB02: no jumper * TB03: no jumper * TB04: no jumper

SW3 is the dip-switch underneath the connector board
TB0* are the four jumpers on the left hand side of the connector board.

=== Database ===

Important database settings: {{{
Cell config: Not hopping
No Concentric Cell = 0
Radiomeasgran =254
No Power Reduction = 0
Excessive distance =0 disabled
}}}

  • the database has to be downloaded from PC via E1 to BS11
  • BCCH channel combination Type 5 or 8 (including SDCCH for SMS)
  • TCH combination 0 or 9
Files (4)
ps_plug.jpg View ps_plug.jpg 128 KB BS11 power supply plug laforge, 10/16/2008 11:27 AM
bs11_connections.jpg View bs11_connections.jpg 149 KB BS11 fully connected with PCM, power, antenna laforge, 10/16/2008 11:29 AM
bs11_power_lmt_cabling.jpg View bs11_power_lmt_cabling.jpg 376 KB Power and LMT cable attached to BS-11 laforge, 02/21/2009 03:36 PM
bs11_connector_covered.jpg View bs11_connector_covered.jpg 362 KB E1 + serial connection board, still covered laforge, 02/21/2009 03:37 PM

Updated by laforge about 8 years ago · 10 revisions

Add picture from clipboard (Maximum size: 48.8 MB)