TC_crcx_and_dlcx_ep_callid_connid
currently fails when specifying the connection ID in the DLCX. It works when only the call-id is specified, without connection ID.
While working on the client FSM I observed the following:
This was sent by the client:
<0011> mgcp_msg.c:64 Received message: line #00: DLCX 3 rtpbridge/0@mgw.osmocom.org MGCP 1.0
<0011> mgcp_msg.c:64 Received message: line #01: C: 4d2
<0011> mgcp_msg.c:64 Received message: line #02: I: 26A09B8CF52BF99F0AA2C95EFA64DA9C
This was the response by the MGW:
<0011> mgcp_msg.c:64 Generated response: line #00: 250 3 OK
<0011> mgcp_msg.c:64 Generated response: line #01: P: PS=0, OS=0, PR=0, OR=0, PL=0, JI=0
<0011> mgcp_msg.c:64 Generated response: line #02: X-Osmo-CP: EC TI=0, TO=0
Probably 250 isnt the right return code?
On Mon, Jan 22, 2018 at 08:32:15PM +0000, dexter [REDMINE] wrote:
Probably 250 isnt the right return code?
I think 250 is exactly the right response code for confirming successful DLCX :)
See spec:
250 The connection was deleted. This return code can only be used
for a successful response to a DeleteConnection command.
- Status changed from New to Feedback
- Assignee changed from dexter to laforge
I wonder if this problem is still present. At least in the last jenkins run I do not see TC_crcx_and_dlcx_ep_callid_connid listed as erroneous.
- Status changed from Feedback to Closed
- % Done changed from 0 to 100