== Power Connection ==
2
3
The Hirschmann plug used for the power connection is called ''Hirschmann Leitungsdose CA 4 LD 09 ZS'' and has the product number
4
932 362-100.
5
6
The pin-out is as follows:
7
 * GND: your shealding/earth line (PE), German:yellow/green wire
8
 * 1: phase (L), German: Brown wire
9
 * 2: not connected
10
 * 3: neutral (N), German: Blue wire
11
12 10 laforge
Please refer to the photograph of a fully wired plug:
13
[[Image(ps_plug.jpg, 25%, align=right)]]
14 9 laforge
15
== E1 Hardware interface ==
16 2 laforge
17
We are using a 120 Ohms balanced connection between the BS11 and a HFC-E1 card.
18
To configure the BS11 hardware correctly, you need to
19
 * open the connection between pin 2 and 3 of the 4 jumpers below connector J01
20
21
=== Cable to RJ45 ===
22
23 8 laforge
The E1 interface[s] of the BS-11 are on some strange BNC-related twinax plugs called "BR2" (Radiall product # 605006000), you can find the PDF data sheet of the connectors at [http://radiall.applixia.net/catalogue/resource?path=PRODUCT/PDF/TDS/coaxialconnectors/R605006000EN.pdf Radiall] and you can buy them online from [http://webradiall.applixia.net/buyonline?PN=R605006000&LANG=en&SUP=FARNELL this link] (which for Germany results in a hyperlink to [http://de.farnell.com/jsp/displayProduct.jsp?sku=4196995 this page of the Farnell webshop] where they cost EUR 16.51 each).
24 7 laforge
25 3 laforge
 * left Y01 PCM in (from BSC): RJ45 pin 4,5
26 1 laforge
 * Y02 PCM out (to BSC): RJ45 pin 1,2
27 7 laforge
 * Y03 PCM left open
28
 * Y04 PCM left open
29 1 laforge
30 10 laforge
31 1 laforge
== Configuration of BTSM Object ==
32
33 10 laforge
=== bs11_config ===
34
35
If you're using [wiki:bs11_config], then the configuration is compiled-in (thus automatically
36
correct) and you can only change it by changing the source code.  
37
38
=== LMT ===
39
40
If you're using LMT, you have to use the following settings for the BTSM object:
41
42 1 laforge
 * BS11 requires PCM30CRC4  64kBit/s no Subslots
43
 * OM Layer on Timeslot 1
44
 * TEI for OM Layer default Siemens is 25 (but configurable in BS11 [wiki:LMT])
45
46
 * the following parameters are not configurable
47
  * RSL Layer on Timeslot 1, too
48
  * TEI for RSL is fixed in  Siemens equipment
49
  * TEI = 0 für TRX0
50
  * TEI = 1 für TRX1
51
  * Attention: if you select OM Layer TEI 0 oder 1, RSL can no longer be brought up
52
53
 * Timeslots for TCHs
54
  * TRX0: TS2 und TS3
55
  * TRX1: TS4 und TS5
56
57 10 laforge
=== E1 interface ===
58 2 laforge
59 1 laforge
LI Objekt:  Line  MULTIDROP
60 4 laforge
61 1 laforge
Impedance 120 Ohm balanced to connect to HFC-E1 board
62 4 laforge
Additionally you will need to change some jumpers on the connector board
63 5 laforge
of BS11:
64
 * dip-switch SW3:
65
  * 1-4: off
66
  * 5-8: on
67
 * TB01: no jumper
68
 * TB02: no jumper
69
 * TB03: no jumper
70 4 laforge
 * TB04: no jumper
71
72 1 laforge
SW3 is the dip-switch underneath the connector board
73 4 laforge
TB0* are the four jumpers on the left hand side of the connector board.
74 1 laforge
75 10 laforge
=== Database ===
76 2 laforge
77 1 laforge
Important database settings:
78
79
 * the database has to be downloaded from PC via E1 to BS11
80
81
82 6 laforge
 * BCCH channel combination Type 5 or 8 (including SDCCH for SMS)
83
 * TCH combination 0 or 9
84 1 laforge
{{{
85
Cell config:    Not hopping
86
                No Concentric Cell = 0
87
                Radiomeasgran =254
88
                No Power Reduction = 0
89
                Excessive distance =0 disabled
90
}}}