SI2quater: osmo-bsc seems unable to send more than three E-UARFCNs in SI2quater System Information

Added by neels almost 4 years ago. Updated over 3 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
07/05/2020
Due date:
% Done:

100%

Spec Reference:

Description

Encoding the E-UARFCNs list in SI2quater seems broken in the presence of multiple E-UARFCNs.

When three E-UARFCN are added in osmo-bsc.cfg, there is one SI2quater sent with a list containing those three.
When a fourth E-UARFCN is added, there is still a single SI2quater sent, but it no longer contains any E-UARFCNs at all.
When a fifth E-UARFCN is added in the config, there are two SI2quaters sent (index 0 and 1), and only the second SI2quater contains exactly the last added E-UARFCN.
With six, two SI2quaters are sent, but only the second one contains E-UARFCNS (the last two configured ones).