Feature #1553

Multi-TRX support of PCU

Added by laforge over 2 years ago. Updated over 1 year ago.

Status:
Closed
Priority:
High
Assignee:
Target version:
-
Start date:
02/23/2016
Due date:
% Done:

10%

Estimated time:
Spec Reference:

Description

In case a BTS has multiple TRX, those multiple TRX should (depending on timeslot configuration) also be available to the PCU, including dynamic TCH / PDCH allocations.

In general Multi-TRX support is present but (completely) untested.

There is some work to be done in the flow control code to correctly compute the per-MS leak rate.


Related issues

Related to OsmoPCU - Feature #1566: Dynamic PDCH / TCH switching: PCU partClosed2016-02-232016-06-10

Related to OsmoPCU - Bug #1775: LC15: No PDCH allocation across two TRXStalled2016-07-12

Related to OsmoBTS - Feature #1648: Verify Multi-TRX support for osmo-bts-trxClosed2016-03-11

Related to OsmoPCU - Feature #1554: per-MS BSSGP flow controlNew2016-02-23

History

#1 Updated by laforge over 2 years ago

  • % Done changed from 0 to 10

we have done some level of manual testing/verification with osmo-bts-litecell15, and it seemed to work quite fine.

More testing (and possibly related bug-fixing) with other BTS hardware is required.

#2 Updated by laforge over 2 years ago

  • Subject changed from Multi-TRX support to Multi-TRX support of PCU
  • Assignee set to msuraev

we need to systematically test this wih all supported BTS models once we have the LTHW tester up and running.

#3 Updated by msuraev over 2 years ago

  • Related to Feature #1566: Dynamic PDCH / TCH switching: PCU part added

#4 Updated by msuraev about 2 years ago

  • Related to Bug #1775: LC15: No PDCH allocation across two TRX added

#5 Updated by msuraev over 1 year ago

  • Related to Feature #1648: Verify Multi-TRX support for osmo-bts-trx added

#6 Updated by laforge over 1 year ago

  • Priority changed from Normal to High

#7 Updated by msuraev over 1 year ago

Note: MS leak rate can by set via vty "flow-control force-ms-leak-rate" command.

#8 Updated by msuraev over 1 year ago

Note: we don't support MS and PFC flow control yet, only BVC flow control procedure is supported. The command above just overrides the default MS leak rate (computed as if 4 TS are used by MS) for BVC flow control.

#9 Updated by msuraev over 1 year ago

#10 Updated by msuraev over 1 year ago

  • Status changed from New to Stalled

#11 Updated by laforge over 1 year ago

  • Status changed from Stalled to Closed

closing the ticket as multi-trx support in the PCU generally seems to work.