1 | 2 | laforge | h1. ITU-T Recommendation V.110 |
---|---|---|---|
2 | 1 | laforge | |
3 | 4 | laforge | V.110 is an ITU standard for bit-rate adaptation of low-speed async serial signals to 64 kbit/s ISDN B-channels. It was primarily used in the context of interworking between GSM Circuit Switched Data (CSD) and ISDN. |
4 | 2 | laforge | |
5 | 4 | laforge | h2. Synchronous |
6 | 1 | laforge | |
7 | 4 | laforge | Rate adaptation of synchronous serial signals of 600, 1200, 2400, 4800, 7200, 9600, 12000, 14400, 19200, 24000, 28800 or 38400 bit/s |
8 | |||
9 | 2 | laforge | h3. Frame structure |
10 | |||
11 | The protocol uses an 80bit (10 byte) frame. The Frame contains a frame sync pattern (similar to e.g. E1 TS0 or TRAU frames) consisting of the first byte and the first bit of every following byte. |
||
12 | |||
13 | Each frame consists of |
||
14 | |||
15 | * 17 bits of above-mentioned frame sync pattern plus: |
||
16 | * 48 D-bits (D1..D48) |
||
17 | * 7 E-bits (E1..E7) |
||
18 | * 8 S/X-bits (S1,S3,S4,S6,S8,S9) |
||
19 | |||
20 | h3. Rate Adaptation Functions |
||
21 | |||
22 | h4. RA1 |
||
23 | |||
24 | The rate-adaptation function RA1 converts from the V-series rates (e.g. 2400bps) to an intermediate rate of 8/16/32/64 kbit/s. |
||
25 | |||
26 | h4. RA2 |
||
27 | 1 | laforge | |
28 | 5 | laforge | RA2 converts from the RA1 output rate of 8/16/32/64 kbit/s to 64 kbit/s and is actually specified in I.460. It's quite simple: |
29 | * in 8 kbit/s, only bit 1 (first bit) of every octet is used |
||
30 | * in 16 kbit/s, only bit 1+2 (first two bits) of every octet are used |
||
31 | * in 32 kbit/s, only bits 1,2,3,4 (first four bits) of every octet are used |
||
32 | |||
33 | All unused bits are set to binary "1". |
||
34 | 4 | laforge | |
35 | h2. Asynchronous |
||
36 | |||
37 | Rate adaptation of asynchronous serial signals of 50, 75, 110, 150, 200, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 12000, 14400, 19200, 24000, 28800 or 38400 bit/s |
||
38 | |||
39 | h3. Rate Adaptation Functions |
||
40 | |||
41 | h4. RA0 |
||
42 | |||
43 | The RA0 function is only used with asynchronous V-series interfaces. Incoming asynchronous data is padded by the addition of stop elements to fit the nearest channel rate defined by 2 × 600 bit/s. Ther esulting synchronous bit stream is then processed with RA1 and RA2 like in the synchronous serial case. |