h1. Siemens NFR2001
2
3 2 laforge
{{thumbnail(DSC01333.JPG, size=500)}}
4
5 1 laforge
h2. Overview
6
7
The Siemens *Normalfrequenzeinrichtung NFR2001* is a clock processing, selection and distribution unit for PDH and SDH networks.  It receives one or multiple reference signals [traditionally from atomic clocks], processes the signals to compensate for transmission errors and synchronizes a two-stage PLL to remove high frequency jitter and wander.
8
9
The NFR2001 generates a local clock referecne which can be provided to PDH and SDH transmission equpment.
10
11
In case the active reference signal fails, the NFR2001 provides fail-over from its internal reference until the firmware has switched over to a new reference signal.
12
13
NFR2001 is internally redundant; all components/modules exist twice and can fail-over whenever needed.  This also allows servicing or upgrade/downgrade while remaining fully operational.
14
15
The NFR2001 allows for the following clock inputs:
16
* 2.048 Mbit/s data signal
17
* 2.048 MHz clock signal
18
* 10 MHz clock signal
19
20
The NFR2001 provides the following clock outputs:
21
* [up to 60] 2.048 MHz clock reference outputs (G.703) 75 ohms unbalanced or 120 ohms balanced.
22
23 2 laforge
h2.  Hardware
24
25
{{thumbnail(DSC01339.JPG,size=400)}}
26
{{thumbnail(DSC01343.JPG,size=400)}}
27
{{thumbnail(DSC01347.JPG,size=400)}}
28
{{thumbnail(DSC01348.JPG,size=400)}}
29
{{thumbnail(DSC01351.JPG,size=400)}}
30 1 laforge
31
h2. Manuals (German)
32
33
* attachment:"NFR2001 Information.pdf"