laforge, 03/10/2024 10:39 AM

1 1 laforge
h1. Siemens NFR2001
2
3
h2. Overview
4
5
The Siemens *Normalfrequenzeinrichtung NFR2001* is a clock processing, selection and distribution unit for PDH and SDH networks.  It receives one or multiple reference signals [traditionally from atomic clocks], processes the signals to compensate for transmission errors and synchronizes a two-stage PLL to remove high frequency jitter and wander.
6
7
The NFR2001 generates a local clock referecne which can be provided to PDH and SDH transmission equpment.
8
9
In case the active reference signal fails, the NFR2001 provides fail-over from its internal reference until the firmware has switched over to a new reference signal.
10
11
NFR2001 is internally redundant; all components/modules exist twice and can fail-over whenever needed.  This also allows servicing or upgrade/downgrade while remaining fully operational.
12
13
The NFR2001 allows for the following clock inputs:
14
* 2.048 Mbit/s data signal
15
* 2.048 MHz clock signal
16
* 10 MHz clock signal
17
18
The NFR2001 provides the following clock outputs:
19
* [up to 60] 2.048 MHz clock reference outputs (G.703) 75 ohms unbalanced or 120 ohms balanced.