Project

General

Profile

Livingston PortMaster 3 » History » Version 11

laforge, 02/20/2022 10:02 AM

1 1 laforge
h1. Livingston Portmaster 3
2 2 laforge
3 5 laforge
@laforge bought two Livingston Portmaster 3 PM3A-1E, which are RAS (Remote Access Server) that
4 2 laforge
* terminates one 1E line (30 B-channels)
5
* provides ISDN dial-up on those channels
6
* provides DSP based modems in case analog modem calls should be handled.
7
8
More details to follow.
9 3 laforge
10
h2. Documentation
11
12
* attachment:portmaster3_hardware_installation.pdf
13
* attachment:portmaster3_configuration.pdf
14 4 laforge
* more below (Attachments)
15 6 laforge
16
h2. Spare Parts / Mods
17
18
h3. Fan
19
20 7 laforge
The original fan is a Fonsan DFB0812M (DC 12V 0.1A) fan by DELTA ELECTRONICS INC. The specs seem to state 2600 RPM / 24.8 dB(A) / 29 cfm.
21 6 laforge
22
I found it too noisy and replaced it with a Noctua NF-A8 FLX with L.N.A (reduced to 1650 rpm / 12.9 dB(A) / 24 cfm)
23
24 1 laforge
Fun fact: The PM3 actually seems to have a 5V -> 12V DC/DC upconverter just for the fan - instead of simply using a 5V fan...
25 7 laforge
26
h3. Power Supply
27
28
One of @laforge's PM3A-E1 had a broken power supply.  The oroginal PSU is an ASTEC LPS1112 rated for 5V/22A output (80W convection cooled, 1120W with 30cfm forced air).
29
30
It was replaced with a Mean Well LRS-150F-5. Mechanical assembly via a custom adapter plate that was fabricated easily from a small piece of aluminium sheet metal with a few drill holes.
31
32
{{thumbnail(PM3-PSU-1.jpg)}}
33 8 laforge
{{thumbnail(PM3-PSU-4.jpg)}}
34
{{thumbnail(PM3-PSU-2.jpg)}}
35 10 laforge
36
h2. Configuration
37
38
h3. route to different telpnet hosts based on called party number
39
40
Assuming one wants to use a PM3 to act as modem bamk for accessing differnt [virtualized] BBSs over telnet, the problem is how to  route the inbound call to a specific telnet IP address.  The non-radius stand-alone configuration of the PM3 only permits either:
41
* automatic forwarding of all calls to one global telnet/rlogin host
42
* allowing the users to enter the hostname for telnet themselves
43 11 laforge
* providing a list of pre-configured telnet desinations to all users (this was used at the 36C3 retronetowrking installation, see [[retro-bbs:36C3]])
44 1 laforge
45 11 laforge
46 10 laforge
However, with the _Call-Check_ radius feature, it should be possibl to receive the called + calling identity before the call is even accepted, and the nin return provide the telnet IP/port to which the call shall be routed.
47
48
Details in
49
* Page 4-17 of the PM3A Radius for Unix manual
50
** PM3A sends _access-request_ with
51
*** User-Name=SETUP.Calling-Station-Id/No-Call-ID
52
*** Service-Type=Call-Check
53
*** Called-Station-Id=SETUP.Called-Station-Id
54
** Radius sends response with
55
*** Login-IP-Host pointing to IP of telnet/rlogin
56
*** Login-Service=(Telnet,Rlogin,TCP-Clear)
57
*** Login-TCP-Port pointing to IP of telnet/rlogin
58 1 laforge
*** Service-Type=Login-User
59 10 laforge
* Page 3-4 of the PortMaster Command Line Reference
60 11 laforge
** @set call-check on@
Add picture from clipboard (Maximum size: 48.8 MB)