EWSD Create DLU » History » Version 1
nt2mku, 07/18/2024 12:43 PM
1 | 1 | nt2mku | h1. EWSD Create DLU |
---|---|---|---|
2 | |||
3 | This guide describes the initial configuration of a new Digital Line Unit, connected via 2M E1 links (not a local DLU). |
||
4 | |||
5 | 1st step: Create the DIU interface at the LTG. The LTG must be of configuration type B (for subscriber access). |
||
6 | Example: LTG 0-8, DIU 3: |
||
7 | <pre>CR LTU: LTG=0-8, LTU=3, TYPE=D30, APPLIC=CCSDLU</pre> |
||
8 | Note: DIU OST is automatically controlled by DLU OST. |
||
9 | |||
10 | 2nd step: Create the DLU object. DLU object ID must be a multiple of 10 (10, 20, 30...). |
||
11 | Example: DLU ID 10, Type DLUA, DIUDLU0 connected to DIU 3 at LTG 0-8: |
||
12 | <pre>CR DLU: DLU=10, TYPE=DLUA, DLUC0=0-8-3-CCS0;</pre> |
||
13 | 3rd step: Enable DC Converters in database: |
||
14 | <pre> |
||
15 | CONF DLUEQ: DLU=10, DCC=0-X,OST=MBL; |
||
16 | CONF DLUEQ: DLU=10, DCC=0-X,OST=ACT; |
||
17 | CONF DLUEQ: DLU=10, DCC=1-X,OST=MBL; |
||
18 | CONF DLUEQ: DLU=10, DCC=0-X,OST=ACT; |
||
19 | CONF DLUEQ: DLU=10, RGMG=X,OST=MBL; |
||
20 | CONF DLUEQ: DLU=10, RGMG=X,OST=ACT; |
||
21 | CONF DLUEQ: DLU=10, RGB=X,OST=MBL; |
||
22 | CONF DLUEQ: DLU=10, RGB=X,OST=ACT; |
||
23 | </pre> |
||
24 | 4th step: Enable the DLU: |
||
25 | <pre> |
||
26 | CONF DLU: DLU=10, OST=MBL; |
||
27 | CONF DLU: DLU=10, OST=ACT; |
||
28 | </pre> |
||
29 | 5th step: Configure and enable DLU modules. |
||
30 | Example: SLMAFPBs in slot 0-0 to 0-7 (upper shelf) and 1-0 to 1-7 (lower shelf): |
||
31 | <pre> |
||
32 | CR DLUMOD: DLU=10, MOD=0-0&&0-7, TYPE=SLMAFPB; |
||
33 | CR DLUMOD: DLU=10, MOD=1-0&&1-7, TYPE=SLMAFPB; |
||
34 | CONF DLUMOD: DLU=10, MOD=0-0&&0-8, OST=MBL; |
||
35 | CONF DLUMOD: DLU=10, MOD=0-0&&0-8, OST=ACT; |
||
36 | CONF DLUMOD: DLU=10, MOD=1-0&&1-8, OST=MBL; |
||
37 | CONF DLUMOD: DLU=10, MOD=1-0&&1-8, OST=ACT; |
||