CSPDN Datex-L » History » Version 9
laforge, 01/30/2023 02:22 PM
1 | 4 | laforge | h1. CSPDN / Datex-L |
---|---|---|---|
2 | 1 | laforge | |
3 | 4 | laforge | CSPDN stands for *Circuit Switched Public Data Network*. The German incarnation of this concept was termed *Datex-L* by Deutsche Bundespost. |
4 | |||
5 | A CSPDN is a dedicated, separate (from PSTN) network providing digital communication services between its users. It is |
||
6 | * *circuit switched* like a telephony network (dedicated circuits/calls/resources are explicitly established and released) |
||
7 | * *digital* unlike a telephony network. The interface between subscriber and network is a digital interface, not an analog line |
||
8 | |||
9 | So conceptually, in a CSPDN like Datex-L, calls between two subscribers are established between digital serial interfaces provided by the telco. |
||
10 | |||
11 | Prior to CSPDNs, the only existing data communications options were: |
||
12 | * using dedicated/leased lines (in Germany so-called [[HfD]] lines) |
||
13 | ** dedicated resources (physical wires) end-to-end. Very expensive. |
||
14 | * using modems in the telephone network |
||
15 | ** very expensive (Modem hardware); only very low speeds at the time (300 bps) |
||
16 | |||
17 | h2. History / Services |
||
18 | |||
19 | CSPDNs are in many ways a higher speed successor of the much earlier [[Telex]] networks that existed for decades at the time of DATEX-L introduction. |
||
20 | |||
21 | Like Telex, CSPDNs are dedicated networks independent of the PSTN. Unlike Telex, CSPDNs are _digital networks_. |
||
22 | |||
23 | 7 | laforge | |_.Name|_.bps|_.Inaugurated|_.Subscriber interface| |
24 | |DATEX-L200|50-200|1967|X.20bis| |
||
25 | |DATEX-L300|300|1976|X.20 or X.20bis| |
||
26 | |DATEX-L2400|2400|1978|X.21 or X.21bis| |
||
27 | |DATEX-L4800|4800|1979|X.21 or X.21bis| |
||
28 | |DATEX-L9600|9600|1979|X.21 or X.21bis| |
||
29 | 4 | laforge | |
30 | h2. Network |
||
31 | |||
32 | 9 | laforge | In a CSPDN network like Datex-L, the user is not concerned with the mode of transmission within the network. The user does not provie their own modem, but the Telco provides a serial digital interface by means of a on-customer-premises [[DCE]] (Data Communications Equipment) to which the user attaches their [[DTE]] (Data Terminal Equipment). |
33 | 4 | laforge | |
34 | It is up to the telco (an _implementation option_) to define the network structure/architecture, the mode of transmission between the elements of the network, etc. |
||
35 | |||
36 | In case of the German Datex-L network, a special type of digital exchanges called [[Siemens_EDS]] was designed and subsequently deployed. |
||
37 | |||
38 | h3. Architecture |
||
39 | |||
40 | 9 | laforge | The Datex-L architecture was based on a hierarchical structure of subscriber-side [[DCE]] equipment attached via subscriber lines to multiplexers (DUST, _Datenumsetzerstelle_) which attached to digital switches (DVST, _Datenvermittlungsstelle_). |
41 | 4 | laforge | |
42 | 9 | laforge | The communication on the _last mile_ (subscriber line) between [[DCE]] and DUST was typically implemented using digital communication in _base band_, so without any form of modulation. Compared with modems for telephone networks, this greatly simplified the complexity and cost of the [[DCE]]. This was only possible due to the network internally is digital, and the only analog segment of the network is between [[DCE]] and DUST. This is a big conceptual difference to a data call using modems in the PSTN, where the entire circuit end-to-end between both subscribers is analog, hundreds or thousands of kilometers long, requiring sophisticated modems. |
43 | 4 | laforge | Communication between the DUST and DVST was implemented over 64kBps links, and wide area communication between DVST was implemented using 2Mbps PCM30E links. |
44 | |||
45 | 5 | laforge | {{graphviz_link() |
46 | graph G { |
||
47 | { rank = same; |
||
48 | dvst1 [shape="hexagon", label="DVST-L + DUST-D\nMünchen"]; |
||
49 | dvst2 [shape="hexagon", label="DVST-L + DUST-D\nNürnberg"]; |
||
50 | } |
||
51 | dvst1 -- dvst2 [label="2Mbps/PCM30"]; |
||
52 | { rank = same; |
||
53 | dust1a [label="DUST-U"]; |
||
54 | dust1b [label="DUST-U"]; |
||
55 | dust2a [label="DUST-U"]; |
||
56 | dust2b [label="DUST-U"]; |
||
57 | } |
||
58 | dvst1 -- dust1a [label="64k"]; |
||
59 | dvst1 -- dust1b [label="64k"]; |
||
60 | dvst2 -- dust2a [label="64k"]; |
||
61 | dvst2 -- dust2b [label="64k"]; |
||
62 | { rank = same; |
||
63 | dce1a1 [shape="box",label="DCE\nat customer"]; |
||
64 | dce2b1 [shape="box",label="DCE\nat csutomer"]; |
||
65 | } |
||
66 | dust1a -- dce1a1 [label="50..9600bps"]; |
||
67 | dust2b -- dce2b1 [label="50..9600bps"]; |
||
68 | { rank= "max"; |
||
69 | dte1a1 [shape="house",label="DTE\nTerminal"]; |
||
70 | dte2b1 [shape="house",label="DTE\nTerminal"]; |
||
71 | } |
||
72 | dte1a1 -- dce1a1 [label="X.20/X.20bis/X.21"]; |
||
73 | dte2b1 -- dce2b1 [label="X.20/X.20bis/X.21"]; |
||
74 | } |
||
75 | }} |
||
76 | |||
77 | 4 | laforge | h4. DVST-L |
78 | |||
79 | DVST-L (_Datenvermittlungsstelle Leitungsorientiert_) were the central switches of the Datex-L network. They were implemented using [[Siemens_EDS]]. |
||
80 | |||
81 | h4. DUST-D |
||
82 | |||
83 | DUST-D (_Datenvermittlungsstelle am Standort der Datenvermittlungsstelle_) were subscriber-side multiplexers that aggregated multiple subscriber lines into 64kbit/s channels *co-located with a DVST-L* |
||
84 | |||
85 | h4. DUST-U |
||
86 | |||
87 | DUST-U (_Datenvermittlungsstelle der unteren Netzebene_) were ubscriber-side multiplexers that aggregated multiple subscriber lines into 64kbit/s channels, *located remotely from a DVST*. |
||
88 | |||
89 | h3. Deployment |
||
90 | |||
91 | The following table shows the scale of the Datex-L deployment all across Western Germany + West Berlin |
||
92 | |||
93 | |_.Network Element|_.Count| |
||
94 | |DVST-L|18| |
||
95 | |DUST-D|18| |
||
96 | |DUST-U|400| |
||
97 | |||
98 | h3. Interational connectivity |
||
99 | |||
100 | Datex-L international connectivity was established |
||
101 | |||
102 | |_.Year|_.Country| |
||
103 | |1970|France| |
||
104 | |1973|Belgium| |
||
105 | 8 | laforge | |1981|Denmark, Finland, Norway, Sweden (NPDN)| |
106 | 1 | laforge | |
107 | 8 | laforge | h2. DCE Equipment |
108 | 1 | laforge | |
109 | {{child_pages}} |
||
110 | 8 | laforge | |
111 | h2. Charges (1981) |
||
112 | |||
113 | h3. One-time setup |
||
114 | |||
115 | h3. Montlhly base fee |
||
116 | |||
117 | |_.Service|_.Interface|_.Monthly base fee (DM)| |
||
118 | |DATEX-L300|X.20|100| |
||
119 | |DATEX-L300|X.20bis|120| |
||
120 | |DATEX-L2400|X.21|170| |
||
121 | |DATEX-L2400|X.21bis|200| |
||
122 | |DATEX-L4800|X.21|270| |
||
123 | |DATEX-L4800|X.21bis|300| |
||
124 | |DATEX-L9600|X.21|370| |
||
125 | |DATEX-L9600|X.21bis|400| |
||
126 | |||
127 | h3. Usage dependent fees |
||
128 | |||
129 | h4. Call establisment fee |
||
130 | |||
131 | Establishment of each call incurred a fee of DM 0.05 (5 Pfennig). |
||
132 | |||
133 | h4. Time based fee |
||
134 | |||
135 | The following charges *in Pfennig incurred every 0.1 second* of an ongoing call: |
||
136 | |||
137 | |_.Service|_.<=50km day|_.<=50km night I|_.<=50km night II|_.>50km day|_.>50km night I|_.>50km night II| |
||
138 | |DATEX-L300|0.063|0.03|0.03|0.117|0.06|0.06| |
||
139 | |DATEX-L2400|0.076|0.036|0.036|0.140|0.072|0.036| |
||
140 | |DATEX-L4800|0.126|0.06|0.06|0.234|0.12|0.06| |
||
141 | |DATEX-L9600|0.214|0.102|0.102|0.398|0.204|0.102| |
||
142 | |||
143 | If you convert the above table into a format showing the cost *in DM for transferring 1 Megabyte of data*, you get: |
||
144 | |||
145 | |_.Service|_.<=50km day|_.<=50km night I|_.<=50km night II|_.>50km day|_.>50km night I|_.>50km night II| |
||
146 | |DATEX-L300|22.02|10.49|10.49|40.89|20.97|20.97| |
||
147 | |DATEX-L2400|3.32|1.57|1.57|6.12|3.15|1.57| |
||
148 | |DATEX-L4800|2.75|1.31|1.31|5.11|2.62|1.31| |
||
149 | |DATEX-L9600|2.34|1.11|1.11|4.35|2.23|1.11| |
||
150 | |||
151 | In order to get an idea in 2022-equivalent EUR pricing, you have to multiply the above 1981 DM prices with a factor of 1.23 (division by 1.956 to get from DM to EUR; multiplication by 2.4 for inflation 1981-2022). So with Datex-L 2400/4800/9600 bps you paid *between 7.53 and 1.37 EUR per Megabyte*. |
||
152 | |||
153 | 2 | laforge | |
154 | h2. Literature |
||
155 | |||
156 | * _Hillebrand, Friedhelm:_ DATEX Infrastruktur der Daten- und Textkommunikation, R.v.Decker's Verlag G. Schenck GmbH, Heidelberg, 1981 |
||
157 | |||
158 | h3. Hillebrand, Kapitel 1 |
||
159 | |||
160 | * _Arnold, F.:_ Endeinrichtungen der öffentlichen Fernmeldenetze, Taschenbuch Telekommunikation, Band 2, R.v. Deckers' Verlag, G. Schenck GmbH, Heidelberg, 1981 |
||
161 | * _Bohm J.:_ Stand und Weiterentwicklung der Datenkommunkation in Fernmeldenetzen der DBP, Zeitschrift für das Post- und Fernmeldewesen, Heft 8, 1978 |
||
162 | * _DBP:_ Planungshilfe für die Datenfernverarbeitung, FTZ-Druckschrift Nr. 114 (4/1980) |
||
163 | * _DBP:_ Vorschriftensammlung für digitale NEtze mit/ohne Verwaltungsanweisungen (Bezug über Postämter) |
||
164 | * _DBP:_ Datelhandbuch (Bezug beim FTZ, T21) |
||
165 | * _Dingeldey, R.:_ Der Ausschuß für Fragen der Datenfernverarbeitung beim FTZ in Nachrichtentechnische Zeitschrift, März 1979 |
||
166 | * _Elias:_ Das Dienstleistungsangebot der DBP für Datenverkehr - Stand und Entwicklungstendenzen, Informatik-Spektrum, 1981, Heft 4 |
||
167 | * _Gabler H., Tietz, W.:_ Datenkommunikation in den Fernmeldenetzen der DBP, Informatik-Spektrum, 1981, Heft 4 |
||
168 | * _Haist, W.:_ Innovation in Fernmeldesystemen im Jahrbuch der DBP 1980, Verlag für Wissenschaft und Leben, G. Heidecker, Bad windsheim |
||
169 | * _Schindler, S., Schröder, J. C. W.:_ Kommunikation in verteilten Systemen, Fachtagung der Gesellschaft für Informatik 1981, Berlin, Heidelberg, New York 1981 |
||
170 | * _Schröder, J. C. W.:_ Anforderungen an die Datenübertragungsdienste der Deutschen Bundespost aus Sicht der Datenververarbeitungsanwender, Der Fernmeldeingenieur, Verlag für Wissenschaft und Leben, 34. Jahrgang, H. 10, Okt,. 1980 |
||
171 | * _Tietz, W. (Bearbeiter):_ CCITT-Empfehlungen der V-Serie und der X-Serie: Band 1: Datenpaketvermittlung - Internationale Standards, 4. Auflage, R.v. Decker's Verlag, G. Schenck, Heidelberg-Hamburg, 1981 |
||
172 | |||
173 | * _Davies, D. W., Barber, D. L.:_ Communications NEtworks for Computers, John Wiley & Sons, London, New York, Sydney, Toronto 1976 |
||
174 | * _Davies D. W., Barber D. L., Price W. L., Saolomonides, C. M.:_ Computer Networks and Their Protocols, John Wiley & Sons, London, New York, Sydney, Toronto 1979. |
||
175 | |||
176 | |||
177 | h3. Hillebrand, Kapitel 2 (Grundlagen der Datex-Dienste) |
||
178 | |||
179 | * _Bocker, P.:_ Datenübertragung, Band I: Grundlagen, Band II: Einrichtugnen und Systeme, Springer Verlag, erlin, Heidelberg, New York 1976/1977 |
||
180 | * _DBP:_ Eigendiagnose in Anwenderdatennetzen, Herahsgegeben vom FTZ, Referat T15, September 1980 |
||
181 | * _BMI, BPM, BMFT:_ Einheitliche höhere Kommunikationsprotokolle für die Öffentliche Verwaltung (EHKP), Bundesanzeiger vom 8. Juli 1980 |
||
182 | * _BMI:_ Spezifikationen der einheitlichen Höheren KLommunikationsprotokolle, Herausgegeben vom Bundesminister des Inneren, Referat OI3. |
||
183 | * _Burklhardt H.-J., Zimmermann H., Bachmann C., Gegenbarth M., Steel T.:_ Beiträge zu offenen Kommunikationssystemen im Sammelband Schindler/Schröder nach 1.6 |
||
184 | * _Heuer, P.:_ Vermittlungsprinzipien in Datenvermittlungssystemen, Der Fernmeldeingenieur, Verlag für Wissenschaft und Leben, 33. Jahrgang, Jan. 1979 |
||
185 | * _Pense, E.:_ Schnittstellen zwischen Datenendeinrichtung und Datenübertragungseinrichtung in neuen Datennetzen in: Fernmeldepraxis, Heft 1/1980 |
||
186 | * _Steuer D.:_ Werdegang und Stand des Projektes PAPA in Technik und Anwendung. Im Sammelband Schindler/Schröder nach 1.6. |
||
187 | * _Tietz W.:_ Offene Kommunikationssysteme und Datenpaketvermittlung in Nachrichtentechnische Zeitschrift 1979, Heft 3 |
||
188 | * _Vogel B.:_ Herstellerunabhängige Netzwerkkonzepte als Planungsalternative, Elektronische Rechenanlagen 1981, Heft 1, Seite 28-34 |
||
189 | * _Wortmann, H.:_ Sachstand der Festlegung "Einheitlicher Höherer Kommunikationsprotokolle" (EHKP) asl nationale Zwischenlösung. Beitrag im Sammelband Schindler/Schröder nach 1.6 |
||
190 | |||
191 | * _Kahl P., Kern K., Nöller H.:_ Technische Überführung der Direktdatenverbindungen bzw. der Anwender-Datennetze in das integrierte Text- und Datennetz (IDN). Informationsschrift des Fernmeldetechnischen Zentralamtes Darmstadt 1980 |
||
192 | * _Lohmann R., Ludwig V., Merz G.:_ Übertragungseinheiten für Datennetze, Siemens-Zeitschrift Heft 10, 1977 |
||
193 | * _Nöller, H.:_ Erste posteigene digitale Knoteneinerichtung für synchrone Datenübertragung in: Fernmeldepraxis 1979, Heft 24 |
||
194 | * _Pumpe, G.:_ Modulares Übertragungssystem für integrierte Fernschreib- und Datennetze, Siemens-Zeitschrift, Heft 4, 1976 |
||
195 | * _Schaffers W.:_ Techni des synchronen Datennetzes. Unterrichtsblätter der DBP Nr. 3, 1981 |
||
196 | |||
197 | h3. Hillebrand, Kapitel 3 (Datex-L) |
||
198 | |||
199 | * _DBP:_ Technische Vorschriften DATEX-L, FTZ-Richtlinie 115 1R1, 1980 |
||
200 | * _DBP:_ Der leitungsvermittelte DATEX-Dienst (DATEX-L), Bundespostministerium Dienststelle 252-3, 1981 |
||
201 | * _Dauth N. (Hrsg.):_ Datenvermittlungstechnik (EDS), R.v. Decker's Verlag, G. Schenck GmbH, Heidelburg, Hamburg, 1978 |
||
202 | * _Dauth, Gruteser, Jendra, Reh, Roggenkamp, Roth, Schaffers, Söring, Steinruck, Tannhäuser, Witt, Ziegler:_ Das elektronische Datenvermittlungssystem EDS, in: Unterrichtsblätter der DBP, erhältlich bei Schriftleitung der Unterrichtsblätter, Fernmeldewesen, Postfach 555, 2000 Hamburg 36 |
||
203 | 3 | laforge | * _Goßlau, K., Kern D., Mitterer H.:_ Siemens System EDS - jetzt auch für 64 kbit/s. Telcom Report, 1980, Heft 6. |
204 | 2 | laforge | * _Kern P. und andere:_ Siemens System EDS, Teil 1-3. Siemens-Zeitschrift, Februar bis Juli 1977 |
205 | 3 | laforge | * _Näßl R., Schaffer B.:_ Das Siemens-System EDS in synchronen Datennetzen. Telcom Report, 1979, Heft 2. |
206 | 2 | laforge | |
207 | h3. Hillebrand, Kapitel 4 (Datex-P) |
||
208 | |||
209 | h4. Literatur zur Paketvermittlungstechnologie |
||
210 | |||
211 | * _CCITT, Gelbbuch:_ Recommandations X.3, X.25, X.28 and X.29 on packet-switched data transmission services, International Telecommunications Union, Genf, ISBN 92-61-00591-8, 1980. |
||
212 | * _FUTURE SYSTEMS:_ Packet Data Communications, 1978, Future Systems Inc, 4 Professional Drive, Suite 141, Gaithersburg, Maryland 20760, USA. |
||
213 | * _Jendra, H.:_ Einführung in die Datenpaketübermittlung (T) und (II) Fernmeldepraxis Band 56 und 57, Fachverlag Schiele & Schön GmbH, Jan./Febr. 1980. |
||
214 | * _Johnson T.:_ Vorzüge der Paketvermittlung bei der Datenfernübertragung in Nachrichtentechnische Zeitschrift 1976, Heft 6, S. 436 — 439. |
||
215 | * _Sarbinowski A.:_ X.25 — Die Paketschnittstelle zwischen Datenendeinrichtungen und öffentlichen Datennetzen, Online, Heft 9/1976. |
||
216 | * _SESA:_ Seminar Datenübertragungsnetze in Paketvermittlungstechnologie, SESA Deutschland GmbH, Frankfurt am Main. |
||
217 | * _Sloman M. S.:_ X.25 explained in computer communications, Vol. 1, No. 6, Dezember 1978. |
||
218 | * _Tietz W. (Bearbeiter):_ Daten-Paketvermittlung, Internationale Standards (Übersetzungen der Empf. X.3, X.25, |
||
219 | X.28, X.29), R.v. Decker’s Verlag, G. Schenck, Heidelberg-Hamburg 1981. |
||
220 | * _Tietz W.:_ Was ist X25, Elektronische Rechenanlagen, Heft 3, 1979, Seite 139— 147. |
||
221 | * _Tietz W.:_ Informationen sind unterwegs im Netzwerk, VDI-Nachrichten, Nr. 38-42, 1978. |
||
222 | |||
223 | h4. Literatur zu DATEX-P |
||
224 | |||
225 | * _Bohm J.:_ Kann DATEX-P das Direktrufnetz ablösen? in bürotechnik (BTA +bto) 1980, Heft 11. |
||
226 | * _Bohm J. und Hillebrand F.:_ Der DATEX-Dienst mit Paketvermittlung (DATEX-P), ein neuer Fernmeldedienst der DBP in Zeitschrift für das Post- und Fernmeldewesen, Januar 1981. |
||
227 | * _DBP:_ Der paketvermittelte DATEX-Dienst (DATEX-P), Bundespostministerium, Dienststellen 252b/252-s, 1981. |
||
228 | * _Hillebrand F.:_ Die Erweiterung des Dienstleistungsangebotes der Deutschen Bundespost durch den paketvermittelten Datexdienst. Jahrbuch der Deutschen Bundespost 1978 (erschienen 1979) Verlag für Wissenschaft und Leben, G. Heidecker, Bad Windsheim. |
||
229 | * _Hillebrand F.:_ Intelligente Infrastruktur für einfache und komplexe Hardware, Computerwoche Nr. 8, 20. 8. 81, Seite 20-22. |
||
230 | * _Runkel D., Tietz W.:_ Das paketvermittelte DATEX-Netz (DATEX-P): Dienst und Technik in Der Fernmeldeingenieur, Teil 1 August 81, Teil 2 Herbst 81, Verlag für Wissenschaft und Leben, G. Heidecker, Bad Windsheim |
||
231 | * _Steinruck K. P.:_ DATEX-P, ein neues Datennetz der DBP in Datenvermittlungstechnik in Fernmeldepraxis 1981, Heft 2. |
||
232 | * _Teilnehmerarbeitskreis DATEX-P:_ Verzeichnis der paketorientierten Datenendeinrichtungen. Bezug FTZ Referat T21. |
||
233 | * _Tietz W.:_ Die Datenpaketvermittlung und DATEX-P in Bürotechnik 1980, Heft 11. |
||
234 | * _Zipprich FH., Meixner B.:_ Das paketvermittelte Datexnetz, Taschenbuch der Fernmeldepraxis 1981, Fachverlag Schiele & Schön GmbH (Hinweise zur Netzplanung). |
||
235 | |||
236 | h4. Literatur zu EURONET |
||
237 | |||
238 | * _DBP:_ Datennetz EURONET, Datenkommunikation in Europa, Datel-Merkblatt 134, Bezug beim FTZ. |
||
239 | * _DBP:_ Datennetz EURONET, Zugangsmöglichkeiten von Datenendeinrichtungen im Bereich der DBP, Datel-Merkblatt 135, Bezug beim FTZ. |
||
240 | * _DBP:_ Datennetz EURONET, Host-Rechner und Datenbanken, Datel-Merkblatt 136, Bezug beim FTZ. |
||
241 | * _DBP:_ Datennetz EURONET, Gebühren für die Benutzung, Datel-Merkblatt 137, Bezug beim FTZ. |
||
242 | * _DBP:_ DATEX-P-Benutzerhandbuch, Herausgeber: Fernmeldetechnisches Zentralamt (T 21). |
||
243 | * _Fähnrich H.:_ EURONET — eine besondere Dienstleistung auf dem Gebiet der Datenkommunikation in Zeitschrift für das Post- und Fernmeldewesen, Heft 1, 1980. |
||
244 | * _Roth, W., Tietz W.:_ Was ist EURONET in Elektronische Rechenanlagen 1979, Heft 6. |
||
245 | * _Schwall A.:_ EURONET — ein europäisches Datenpaketvermittlungsnetz, Jahrbuch der Deutschen Bundespost 1978, Verlag für Wissenschaft und Leben, G. Heidecker, Bad Windsheim. |
||
246 | |||
247 | h3. Hillebrand, Kapitel 6 (Ausland) |
||
248 | |||
249 | * _DBP:_ Vorschriftensammlung für den Fernmeldeverkehr mit dem Ausland mit/ohne Verwaltungsanweisungen (Bezug über Postämter). |
||
250 | * _DBP:_ Pressemitteilungen zu den geplanten Verkehrsaufnahmen von DATEX-P nach Frankreich, England, Spanien und Schweden (Bundespostministerium, Pressestelle). |
||
251 | * _EURODATA Foundation:_ Pläne der europäischen Fernmeldeverwaltungen für Öffentliche Datennetze (Nähere Auskunft FTZ, T 23-5. Bezug EURODATA Foundation, Broad Street House, 55 Old Broad Street, London, EC2M 1RX) |
||
252 | * _EURODATA Foundation:_ Yearbook (Auskunft und Bezug wie bei vorstehender Quelle). |
||
253 | * _Hausmann, G.:_ Internationale Zusammenarbeit der DBP auf dem Gebiet des Fernmeldewesens in Bundespost 1981, herausgegeben vom Bundespostministerium Pressestelle. |
||
254 | * _Hübner T., Tietz W.:_ Öffentliche Datennetze in Europa in Nachrichtentechnische Zeitschrift 1980, Heft 5. |
||
255 | |||
256 | h3. Hillebrand, Kapitel 7 (Sicherheitskonzept) |
||
257 | |||
258 | * _DBP:_ Neuer erweiterter Entstörungsservice für Telex- und DATEX-Hauptanschlüsse sowie für Hauptanschlüsse für Direktruf und internationale Mietleitungen, Datelmerkblatt Nr. 128 (Bezug beim FTZ). |
||
259 | |||
260 | h3. Hillebrand, Kapitel 8 (BTX) |
||
261 | |||
262 | * _DBP:_ Bildschirmtext, Beschreibung und Anwendungsmöglichkeiten, 1977 (Bezug beim FTZ, Referat T24). |
||
263 | * _Döring J.:_ Der externe Rechner im Bildschirmtext-Rechnerverbund. Beitrag im Sammelband Schindler/Schröder nach 1.6. |
||
264 | * _Kammerer-Jöbges B.:_ Überblick über Anwendungsbereiche von Bildschirmtext. Beitrag im Sammelband Schindler/Schröder nach 1.6. |
||
265 | |||
266 | h3. Hillebrand, Kapitel 9 (Auswahl) |
||
267 | |||
268 | * _DBP:_ Datel-Handbuch (Kapitel Entscheidungshilfe) (Bezug beim FTZ, T 21) |
||
269 | * _Georg:_ Datenkommunikationsnetze der DBP-Übersicht und Auswahlkriterien in Nachrichtentechnische Zeitschrift März 1979 |