Project

General

Profile

CSPDN Datex-L » History » Version 9

laforge, 01/30/2023 02:22 PM

1 4 laforge
h1. CSPDN / Datex-L
2 1 laforge
3 4 laforge
CSPDN stands for *Circuit Switched Public Data Network*.  The German incarnation of this concept was termed *Datex-L* by Deutsche Bundespost.
4
5
A CSPDN is a dedicated, separate (from PSTN) network providing digital communication services between its users. It is
6
* *circuit switched* like a telephony network (dedicated circuits/calls/resources are explicitly established and released)
7
* *digital* unlike a telephony network.  The interface between subscriber and network is a digital interface, not an analog line
8
9
So conceptually, in a CSPDN like Datex-L, calls between two subscribers are established between digital serial interfaces provided by the telco.
10
11
Prior to CSPDNs, the only existing data communications options were:
12
* using dedicated/leased lines (in Germany so-called [[HfD]] lines)
13
** dedicated resources (physical wires) end-to-end. Very expensive.
14
* using modems in the telephone network
15
** very expensive (Modem hardware); only very low speeds at the time (300 bps)
16
17
h2. History / Services
18
19
CSPDNs are in many ways a higher speed successor of the much earlier [[Telex]] networks that existed for decades at the time of DATEX-L introduction.
20
21
Like Telex, CSPDNs are dedicated networks independent of the PSTN.  Unlike Telex, CSPDNs are _digital networks_. 
22
23 7 laforge
|_.Name|_.bps|_.Inaugurated|_.Subscriber interface|
24
|DATEX-L200|50-200|1967|X.20bis|
25
|DATEX-L300|300|1976|X.20 or X.20bis|
26
|DATEX-L2400|2400|1978|X.21 or X.21bis|
27
|DATEX-L4800|4800|1979|X.21 or X.21bis|
28
|DATEX-L9600|9600|1979|X.21 or X.21bis|
29 4 laforge
30
h2. Network
31
32 9 laforge
In a CSPDN network like Datex-L, the user is not concerned with the mode of transmission within the network. The user does not provie their own modem, but the Telco provides a serial digital interface by means of a on-customer-premises [[DCE]] (Data Communications Equipment) to which the user attaches their [[DTE]] (Data Terminal Equipment).
33 4 laforge
34
It is up to the telco (an _implementation option_) to define the network structure/architecture, the mode of transmission between the elements of the network, etc.
35
36
In case of the German Datex-L network, a special type of digital exchanges called [[Siemens_EDS]] was designed and subsequently deployed.
37
38
h3. Architecture
39
40 9 laforge
The Datex-L architecture was based on a hierarchical structure of subscriber-side [[DCE]] equipment attached via subscriber lines to multiplexers (DUST, _Datenumsetzerstelle_) which attached to digital switches (DVST, _Datenvermittlungsstelle_).
41 4 laforge
42 9 laforge
The communication on the _last mile_ (subscriber line) between [[DCE]] and DUST was typically implemented using digital communication in _base band_, so without any form of modulation.  Compared with modems for telephone networks, this greatly simplified the complexity and cost of the [[DCE]].  This was only possible due to the network internally is digital, and the only analog segment of the network is between [[DCE]] and DUST.  This is a big conceptual difference to a data call using modems in the PSTN, where the entire circuit end-to-end between both subscribers is analog, hundreds or thousands of kilometers long, requiring sophisticated modems.
43 4 laforge
Communication between the DUST and DVST was implemented over 64kBps links, and wide area communication between DVST was implemented using 2Mbps PCM30E links.
44
45 5 laforge
{{graphviz_link()
46
graph G {
47
  { rank = same;
48
    dvst1 [shape="hexagon", label="DVST-L + DUST-D\nMünchen"];
49
    dvst2 [shape="hexagon", label="DVST-L + DUST-D\nNürnberg"];
50
  }
51
  dvst1 -- dvst2 [label="2Mbps/PCM30"];
52
  { rank = same;
53
    dust1a [label="DUST-U"];
54
    dust1b [label="DUST-U"];
55
    dust2a [label="DUST-U"];
56
    dust2b [label="DUST-U"];
57
  }
58
  dvst1 -- dust1a [label="64k"];
59
  dvst1 -- dust1b [label="64k"];
60
  dvst2 -- dust2a [label="64k"];
61
  dvst2 -- dust2b [label="64k"];
62
  { rank = same;
63
    dce1a1 [shape="box",label="DCE\nat customer"];
64
    dce2b1 [shape="box",label="DCE\nat csutomer"];
65
  }
66
  dust1a -- dce1a1 [label="50..9600bps"];
67
  dust2b -- dce2b1 [label="50..9600bps"];
68
  { rank= "max";
69
    dte1a1 [shape="house",label="DTE\nTerminal"];
70
    dte2b1 [shape="house",label="DTE\nTerminal"];
71
  }
72
  dte1a1 -- dce1a1 [label="X.20/X.20bis/X.21"];
73
  dte2b1 -- dce2b1 [label="X.20/X.20bis/X.21"];
74
}
75
}}
76
77 4 laforge
h4. DVST-L
78
79
DVST-L (_Datenvermittlungsstelle Leitungsorientiert_) were the central switches of the Datex-L network. They were implemented using [[Siemens_EDS]].
80
81
h4. DUST-D
82
83
DUST-D (_Datenvermittlungsstelle am Standort der Datenvermittlungsstelle_) were subscriber-side multiplexers that aggregated multiple subscriber lines into 64kbit/s channels *co-located with a DVST-L*
84
85
h4. DUST-U
86
87
DUST-U (_Datenvermittlungsstelle der unteren Netzebene_) were ubscriber-side multiplexers that aggregated multiple subscriber lines into 64kbit/s channels, *located remotely from a DVST*.
88
89
h3. Deployment
90
91
The following table shows the scale of the Datex-L deployment all across Western Germany + West Berlin
92
93
|_.Network Element|_.Count|
94
|DVST-L|18|
95
|DUST-D|18|
96
|DUST-U|400|
97
98
h3. Interational connectivity
99
100
Datex-L international connectivity was established
101
102
|_.Year|_.Country|
103
|1970|France|
104
|1973|Belgium|
105 8 laforge
|1981|Denmark, Finland, Norway, Sweden (NPDN)|
106 1 laforge
107 8 laforge
h2. DCE Equipment
108 1 laforge
109
{{child_pages}}
110 8 laforge
111
h2. Charges (1981)
112
113
h3. One-time setup
114
115
h3. Montlhly base fee
116
117
|_.Service|_.Interface|_.Monthly base fee (DM)|
118
|DATEX-L300|X.20|100|
119
|DATEX-L300|X.20bis|120|
120
|DATEX-L2400|X.21|170|
121
|DATEX-L2400|X.21bis|200|
122
|DATEX-L4800|X.21|270|
123
|DATEX-L4800|X.21bis|300|
124
|DATEX-L9600|X.21|370|
125
|DATEX-L9600|X.21bis|400|
126
127
h3. Usage dependent fees
128
129
h4. Call establisment fee
130
131
Establishment of each call incurred a fee of DM 0.05 (5 Pfennig).
132
133
h4. Time based fee
134
135
The following charges *in Pfennig incurred every 0.1 second* of an ongoing call:
136
137
|_.Service|_.<=50km day|_.<=50km night I|_.<=50km night II|_.>50km day|_.>50km night I|_.>50km night II|
138
|DATEX-L300|0.063|0.03|0.03|0.117|0.06|0.06|
139
|DATEX-L2400|0.076|0.036|0.036|0.140|0.072|0.036|
140
|DATEX-L4800|0.126|0.06|0.06|0.234|0.12|0.06|
141
|DATEX-L9600|0.214|0.102|0.102|0.398|0.204|0.102|
142
143
If you convert the above table into a format showing the cost *in DM for transferring 1 Megabyte of data*, you get:
144
145
|_.Service|_.<=50km day|_.<=50km night I|_.<=50km night II|_.>50km day|_.>50km night I|_.>50km night II|
146
|DATEX-L300|22.02|10.49|10.49|40.89|20.97|20.97|
147
|DATEX-L2400|3.32|1.57|1.57|6.12|3.15|1.57|
148
|DATEX-L4800|2.75|1.31|1.31|5.11|2.62|1.31|
149
|DATEX-L9600|2.34|1.11|1.11|4.35|2.23|1.11|
150
151
In order to get an idea in 2022-equivalent EUR pricing, you have to multiply the above 1981 DM prices with  a factor of 1.23 (division by 1.956 to get from DM to EUR; multiplication by 2.4 for inflation 1981-2022).  So with Datex-L 2400/4800/9600 bps you paid *between 7.53 and 1.37 EUR per Megabyte*.
152
153 2 laforge
154
h2. Literature
155
156
* _Hillebrand, Friedhelm:_ DATEX Infrastruktur der Daten- und Textkommunikation, R.v.Decker's Verlag G. Schenck GmbH, Heidelberg, 1981
157
158
h3. Hillebrand, Kapitel 1
159
160
* _Arnold, F.:_ Endeinrichtungen der öffentlichen Fernmeldenetze, Taschenbuch Telekommunikation, Band 2, R.v. Deckers' Verlag, G. Schenck GmbH, Heidelberg, 1981
161
* _Bohm J.:_ Stand und Weiterentwicklung der Datenkommunkation in Fernmeldenetzen der DBP, Zeitschrift für das Post- und Fernmeldewesen, Heft 8, 1978
162
* _DBP:_ Planungshilfe für die Datenfernverarbeitung, FTZ-Druckschrift Nr. 114 (4/1980)
163
* _DBP:_ Vorschriftensammlung für digitale NEtze mit/ohne Verwaltungsanweisungen (Bezug über Postämter)
164
* _DBP:_ Datelhandbuch (Bezug beim FTZ, T21)
165
* _Dingeldey, R.:_ Der Ausschuß für Fragen der Datenfernverarbeitung beim FTZ in Nachrichtentechnische Zeitschrift, März 1979
166
* _Elias:_ Das Dienstleistungsangebot der DBP für Datenverkehr - Stand und Entwicklungstendenzen, Informatik-Spektrum, 1981, Heft 4
167
* _Gabler H., Tietz, W.:_ Datenkommunikation in den Fernmeldenetzen der DBP, Informatik-Spektrum, 1981, Heft 4
168
* _Haist, W.:_ Innovation in Fernmeldesystemen im Jahrbuch der DBP 1980, Verlag für Wissenschaft und Leben, G. Heidecker, Bad windsheim
169
* _Schindler, S., Schröder, J. C. W.:_ Kommunikation in verteilten Systemen, Fachtagung der Gesellschaft für Informatik 1981, Berlin, Heidelberg, New York 1981
170
* _Schröder, J. C. W.:_ Anforderungen an die Datenübertragungsdienste der Deutschen Bundespost aus Sicht der Datenververarbeitungsanwender, Der Fernmeldeingenieur, Verlag für Wissenschaft und Leben, 34. Jahrgang, H. 10, Okt,. 1980
171
* _Tietz, W. (Bearbeiter):_ CCITT-Empfehlungen der V-Serie und der X-Serie: Band 1: Datenpaketvermittlung - Internationale Standards, 4. Auflage, R.v. Decker's Verlag, G. Schenck, Heidelberg-Hamburg, 1981
172
173
* _Davies, D. W., Barber, D. L.:_ Communications NEtworks for Computers, John Wiley & Sons, London, New York, Sydney, Toronto 1976
174
* _Davies D. W., Barber D. L., Price W. L., Saolomonides, C. M.:_ Computer Networks and Their Protocols, John Wiley & Sons, London, New York, Sydney, Toronto 1979.
175
176
177
h3. Hillebrand, Kapitel 2 (Grundlagen der Datex-Dienste)
178
179
* _Bocker, P.:_ Datenübertragung, Band I: Grundlagen, Band II: Einrichtugnen und Systeme, Springer Verlag, erlin, Heidelberg, New York 1976/1977
180
* _DBP:_  Eigendiagnose in Anwenderdatennetzen, Herahsgegeben vom FTZ, Referat T15, September 1980
181
* _BMI, BPM, BMFT:_ Einheitliche höhere Kommunikationsprotokolle für die Öffentliche Verwaltung (EHKP), Bundesanzeiger vom 8. Juli 1980
182
* _BMI:_ Spezifikationen der einheitlichen Höheren KLommunikationsprotokolle, Herausgegeben vom Bundesminister des Inneren, Referat OI3.
183
* _Burklhardt H.-J., Zimmermann H., Bachmann C., Gegenbarth M., Steel T.:_ Beiträge zu offenen Kommunikationssystemen im Sammelband Schindler/Schröder nach 1.6
184
* _Heuer, P.:_ Vermittlungsprinzipien in Datenvermittlungssystemen, Der Fernmeldeingenieur, Verlag für Wissenschaft und Leben, 33. Jahrgang, Jan. 1979
185
* _Pense, E.:_ Schnittstellen zwischen Datenendeinrichtung und Datenübertragungseinrichtung in neuen Datennetzen in: Fernmeldepraxis, Heft 1/1980
186
* _Steuer D.:_ Werdegang und Stand des Projektes PAPA in Technik und Anwendung. Im Sammelband Schindler/Schröder nach 1.6.
187
* _Tietz W.:_ Offene Kommunikationssysteme und Datenpaketvermittlung in Nachrichtentechnische Zeitschrift 1979, Heft 3
188
* _Vogel B.:_ Herstellerunabhängige Netzwerkkonzepte als Planungsalternative, Elektronische Rechenanlagen 1981, Heft 1, Seite 28-34
189
* _Wortmann, H.:_ Sachstand der Festlegung "Einheitlicher Höherer Kommunikationsprotokolle" (EHKP) asl nationale Zwischenlösung. Beitrag im Sammelband Schindler/Schröder nach 1.6
190
191
* _Kahl P., Kern K., Nöller H.:_ Technische Überführung der Direktdatenverbindungen bzw. der Anwender-Datennetze in das integrierte Text- und Datennetz (IDN). Informationsschrift des Fernmeldetechnischen Zentralamtes Darmstadt 1980
192
* _Lohmann R., Ludwig V., Merz G.:_ Übertragungseinheiten für Datennetze, Siemens-Zeitschrift Heft 10, 1977
193
* _Nöller, H.:_ Erste posteigene digitale Knoteneinerichtung für synchrone  Datenübertragung in: Fernmeldepraxis 1979, Heft 24
194
* _Pumpe, G.:_ Modulares Übertragungssystem für integrierte Fernschreib- und Datennetze, Siemens-Zeitschrift, Heft 4, 1976
195
* _Schaffers W.:_ Techni des synchronen Datennetzes. Unterrichtsblätter der DBP Nr. 3, 1981
196
197
h3. Hillebrand, Kapitel 3 (Datex-L)
198
199
* _DBP:_ Technische Vorschriften DATEX-L, FTZ-Richtlinie 115 1R1, 1980
200
* _DBP:_ Der leitungsvermittelte DATEX-Dienst (DATEX-L), Bundespostministerium Dienststelle 252-3, 1981
201
* _Dauth N. (Hrsg.):_ Datenvermittlungstechnik (EDS), R.v. Decker's Verlag, G. Schenck GmbH, Heidelburg, Hamburg, 1978
202
* _Dauth, Gruteser, Jendra, Reh, Roggenkamp, Roth, Schaffers, Söring, Steinruck, Tannhäuser, Witt, Ziegler:_ Das elektronische Datenvermittlungssystem EDS, in: Unterrichtsblätter der DBP,  erhältlich bei Schriftleitung der Unterrichtsblätter, Fernmeldewesen, Postfach 555, 2000 Hamburg 36
203 3 laforge
* _Goßlau, K., Kern D., Mitterer H.:_ Siemens System EDS - jetzt auch für 64 kbit/s. Telcom Report, 1980, Heft 6.
204 2 laforge
* _Kern P. und andere:_ Siemens System EDS, Teil 1-3. Siemens-Zeitschrift, Februar bis Juli 1977
205 3 laforge
* _Näßl R., Schaffer B.:_ Das Siemens-System EDS in synchronen Datennetzen. Telcom Report, 1979, Heft 2.
206 2 laforge
207
h3. Hillebrand, Kapitel 4 (Datex-P)
208
209
h4. Literatur zur Paketvermittlungstechnologie
210
211
* _CCITT, Gelbbuch:_ Recommandations X.3, X.25, X.28 and X.29 on packet-switched data transmission services, International Telecommunications Union, Genf, ISBN 92-61-00591-8, 1980.
212
* _FUTURE SYSTEMS:_ Packet Data Communications, 1978, Future Systems Inc, 4 Professional Drive, Suite 141, Gaithersburg, Maryland 20760, USA.
213
* _Jendra, H.:_ Einführung in die Datenpaketübermittlung (T) und (II) Fernmeldepraxis Band 56 und 57, Fachverlag Schiele & Schön GmbH, Jan./Febr. 1980.
214
* _Johnson T.:_ Vorzüge der Paketvermittlung bei der Datenfernübertragung in Nachrichtentechnische Zeitschrift 1976, Heft 6, S. 436 — 439.
215
* _Sarbinowski A.:_ X.25 — Die Paketschnittstelle zwischen Datenendeinrichtungen und öffentlichen Datennetzen, Online, Heft 9/1976.
216
* _SESA:_ Seminar Datenübertragungsnetze in Paketvermittlungstechnologie, SESA Deutschland GmbH, Frankfurt am Main.
217
* _Sloman M. S.:_ X.25 explained in computer communications, Vol. 1, No. 6, Dezember 1978.
218
* _Tietz W. (Bearbeiter):_ Daten-Paketvermittlung, Internationale Standards (Übersetzungen der Empf. X.3, X.25,
219
X.28, X.29), R.v. Decker’s Verlag, G. Schenck, Heidelberg-Hamburg 1981.
220
* _Tietz W.:_ Was ist X25, Elektronische Rechenanlagen, Heft 3, 1979, Seite 139— 147.
221
* _Tietz W.:_ Informationen sind unterwegs im Netzwerk, VDI-Nachrichten, Nr. 38-42, 1978.
222
223
h4. Literatur zu DATEX-P
224
225
* _Bohm J.:_ Kann DATEX-P das Direktrufnetz ablösen? in bürotechnik (BTA +bto) 1980, Heft 11.
226
* _Bohm J. und Hillebrand F.:_ Der DATEX-Dienst mit Paketvermittlung (DATEX-P), ein neuer Fernmeldedienst der DBP in Zeitschrift für das Post- und Fernmeldewesen, Januar 1981.
227
* _DBP:_ Der paketvermittelte DATEX-Dienst (DATEX-P), Bundespostministerium, Dienststellen 252b/252-s, 1981.
228
* _Hillebrand F.:_ Die Erweiterung des Dienstleistungsangebotes der Deutschen Bundespost durch den paketvermittelten Datexdienst. Jahrbuch der Deutschen Bundespost 1978 (erschienen 1979) Verlag für Wissenschaft und Leben, G. Heidecker, Bad Windsheim.
229
* _Hillebrand F.:_ Intelligente Infrastruktur für einfache und komplexe Hardware, Computerwoche Nr. 8, 20. 8. 81, Seite 20-22.
230
* _Runkel D., Tietz W.:_ Das paketvermittelte DATEX-Netz (DATEX-P): Dienst und Technik in Der Fernmeldeingenieur, Teil 1 August 81, Teil 2 Herbst 81, Verlag für Wissenschaft und Leben, G. Heidecker, Bad Windsheim
231
* _Steinruck K. P.:_ DATEX-P, ein neues Datennetz der DBP in Datenvermittlungstechnik in Fernmeldepraxis 1981, Heft 2.
232
* _Teilnehmerarbeitskreis DATEX-P:_ Verzeichnis der paketorientierten Datenendeinrichtungen. Bezug FTZ Referat T21.
233
* _Tietz W.:_ Die Datenpaketvermittlung und DATEX-P in Bürotechnik 1980, Heft 11.
234
* _Zipprich FH., Meixner B.:_ Das paketvermittelte Datexnetz, Taschenbuch der Fernmeldepraxis 1981, Fachverlag Schiele & Schön GmbH (Hinweise zur Netzplanung).
235
236
h4. Literatur zu EURONET
237
238
* _DBP:_ Datennetz EURONET, Datenkommunikation in Europa, Datel-Merkblatt 134, Bezug beim FTZ.
239
* _DBP:_ Datennetz EURONET, Zugangsmöglichkeiten von Datenendeinrichtungen im Bereich der DBP, Datel-Merkblatt 135, Bezug beim FTZ.
240
* _DBP:_ Datennetz EURONET, Host-Rechner und Datenbanken, Datel-Merkblatt 136, Bezug beim FTZ.
241
* _DBP:_ Datennetz EURONET, Gebühren für die Benutzung, Datel-Merkblatt 137, Bezug beim FTZ.
242
* _DBP:_ DATEX-P-Benutzerhandbuch, Herausgeber: Fernmeldetechnisches Zentralamt (T 21).
243
* _Fähnrich H.:_ EURONET — eine besondere Dienstleistung auf dem Gebiet der Datenkommunikation in Zeitschrift für das Post- und Fernmeldewesen, Heft 1, 1980.
244
* _Roth, W., Tietz W.:_ Was ist EURONET in Elektronische Rechenanlagen 1979, Heft 6.
245
* _Schwall A.:_ EURONET — ein europäisches Datenpaketvermittlungsnetz, Jahrbuch der Deutschen Bundespost 1978, Verlag für Wissenschaft und Leben, G. Heidecker, Bad Windsheim.
246
247
h3. Hillebrand, Kapitel 6 (Ausland)
248
249
* _DBP:_ Vorschriftensammlung für den Fernmeldeverkehr mit dem Ausland mit/ohne Verwaltungsanweisungen (Bezug über Postämter).
250
* _DBP:_ Pressemitteilungen zu den geplanten Verkehrsaufnahmen von DATEX-P nach Frankreich, England, Spanien und Schweden (Bundespostministerium, Pressestelle).
251
* _EURODATA Foundation:_ Pläne der europäischen Fernmeldeverwaltungen für Öffentliche Datennetze (Nähere Auskunft FTZ, T 23-5. Bezug EURODATA Foundation, Broad Street House, 55 Old Broad Street, London, EC2M 1RX)
252
* _EURODATA Foundation:_ Yearbook (Auskunft und Bezug wie bei vorstehender Quelle).
253
* _Hausmann, G.:_ Internationale Zusammenarbeit der DBP auf dem Gebiet des Fernmeldewesens in Bundespost 1981, herausgegeben vom Bundespostministerium Pressestelle.
254
* _Hübner T., Tietz W.:_ Öffentliche Datennetze in Europa in Nachrichtentechnische Zeitschrift 1980, Heft 5.
255
256
h3. Hillebrand, Kapitel 7 (Sicherheitskonzept)
257
258
* _DBP:_ Neuer erweiterter Entstörungsservice für Telex- und DATEX-Hauptanschlüsse sowie für Hauptanschlüsse für Direktruf und internationale Mietleitungen, Datelmerkblatt Nr. 128 (Bezug beim FTZ).
259
260
h3. Hillebrand, Kapitel 8 (BTX)
261
262
* _DBP:_ Bildschirmtext, Beschreibung und Anwendungsmöglichkeiten, 1977 (Bezug beim FTZ, Referat T24).
263
* _Döring J.:_ Der externe Rechner im Bildschirmtext-Rechnerverbund. Beitrag im Sammelband Schindler/Schröder nach 1.6.
264
* _Kammerer-Jöbges B.:_ Überblick über Anwendungsbereiche von Bildschirmtext. Beitrag im Sammelband Schindler/Schröder nach 1.6.
265
266
h3. Hillebrand, Kapitel 9 (Auswahl)
267
268
* _DBP:_ Datel-Handbuch (Kapitel Entscheidungshilfe) (Bezug beim FTZ, T 21)
269
* _Georg:_ Datenkommunikationsnetze der DBP-Übersicht und Auswahlkriterien in Nachrichtentechnische Zeitschrift März 1979
Add picture from clipboard (Maximum size: 48.8 MB)