Project

General

Profile

Port Numbers » History » Version 41

dexter, 11/14/2017 02:53 PM

1 38 laforge
{{>toc}}
2 1 laforge
3 11 laforge
h1. List of TCP/UDP Port numbers
4
5 1 laforge
Below is a list of TCP/UDP port numbers as it is used by Osmocom GSM related software.
6
7 12 laforge
|_.L4|_.Port Number|_.Purpose|_.Software|
8 41 dexter
|UDP|2427|MGCP GW|[[OsmoBSC:Osmo-bsc_mgcp|osmo-bsc_mgcp]], [[OsmoMGW:]]|
9 12 laforge
|TCP|2775|SMPP|[[OsmoNITB:]]|
10 39 neels
|SCTP|2905|M3UA|[[OsmoSTP:]]|
11 12 laforge
|TCP|3002|A-bis/IP OML|[[OsmoBTS:]], [[OsmoBSC:]], [[OsmoNITB:]]|
12
|TCP|3003|A-bis/IP RSL|[[OsmoBTS:]], [[OsmoBSC:]], [[OsmoNITB:]]|
13 29 neels
|TCP|4222|GSUP|[[OsmoHLR:]]|
14 28 laforge
|TCP|4237|telnet (VTY)|reserved for osmo-pcap-client|
15
|TCP|4238|telnet (VTY)|reserved for osmo-pcap-server|
16 26 neels
|TCP|4239|telnet (VTY)|[[OsmoSTP:]]|
17 12 laforge
|TCP|4240|telnet (VTY)|[[OsmoPCU:]], osmo_pcap_client|
18
|TCP|4241|telnet (VTY)|[[OsmoBTS:]], osmo_pcap_server|
19 20 neels
|TCP|4242|telnet (VTY)|[[OsmoNITB:]], [[OsmoBSC:]], [[cellmgr-ng:cellmgr_ng]]|
20 13 neels
|TCP|4243|telnet (VTY)|[[OsmoBSC:Osmo-bsc_mgcp|osmo-bsc_mgcp]]|
21 40 dexter
|TCP|4243|telnet (VTY)|[[OsmoMGW:]]|
22 13 neels
|TCP|4244|telnet (VTY)|[[OpenBSC:bsc_nat|osmo-bsc_nat]]|
23 12 laforge
|TCP|4245|telnet (VTY)|[[OsmoSGSN:]]|
24 13 neels
|TCP|4246|telnet (VTY)|[[OpenBSC:osmo-gbproxy]]|
25 12 laforge
|TCP|4247|telnet (VTY)|[[OsmocomBB:]]|
26
|TCP|4249|Control Interface|[[OsmoNITB:]]/[[OsmoBSC:]]|
27 13 neels
|TCP|4250|Control Interface|[[OpenBSC:bsc_nat|osmo-bsc_nat]]|
28 12 laforge
|TCP|4251|Control Interface|[[OsmoSGSN:]]|
29 17 neels
|TCP|4252|telnet (VTY)|sysmobts-mgr|
30 16 neels
|TCP|4253|telnet (VTY)|[[OsmoGTPHub]]|
31 37 neels
|TCP|4254|telnet (VTY)|[[OsmoMSC:]]|
32
|TCP|4255|Control Interface|[[OsmoMSC:]]|
33 18 neels
|TCP|4256|telnet (VTY)|[[miscellaneous-projects:Osmo-sip-connector]]|
34 31 laforge
|TCP|4257|Control Interface|[[OpenGGSN:]]/[[OpenGGSN:OsmoGGSN]]|
35 27 neels
|TCP|4258|telnet (VTY)|[[OsmoHLR:]]|
36
|TCP|4259|Control Interface|[[OsmoHLR:]]|
37 36 neels
|TCP|4260|telnet (VTY)|[[OpenGGSN:OsmoGGSN]]|
38 13 neels
|UDP|4729|GSMTAP|Almost every osmocom project|
39 19 neels
|TCP|5000|A/IP|[[OpenBSC:bsc_nat|osmo-bsc_nat]]|
40 20 neels
|UDP|23000|NS-over-IP|[[OsmoSGSN:]],[[OsmoPCU:]],[[OpenBSC:osmo-gbproxy]]|
41 21 neels
42
See also:
43
44
* https://git.osmocom.org/libosmocore/tree/include/osmocom/vty/ports.h
45
* https://git.osmocom.org/libosmocore/tree/include/osmocom/ctrl/ports.h
46
* https://git.osmocom.org/osmo-gsm-manuals/tree/common/chapters/port_numbers.adoc
47
48
_Modifications should be kept in sync between this wiki page, the header files
49 1 laforge
and the osmo-gsm-manuals._
50 38 laforge
51
h1. /etc/services
52
53
If you are continuously working with osmocom software, as a convenience helper, you might add something like
54
55
<pre>
56
osmo-pcap-client        4237/tcp
57
osmo-pcap-server        4238/tcp
58
osmo-stp                4239/tcp
59
osmo-pcu                4240/tcp
60
osmo-bts                4241/tcp
61
osmo-bsc                4242/tcp        osmo-nitb
62
osmo-mgw                4243/tcp        osmo-bsc_mgcp
63
osmo-bsc_nat            4244/tcp
64
osmo-sgsn               4245/tcp
65
osmo-gbproxy            4246/tcp
66
osmocombb               4247/tcp
67
sysmobts-mgr            4252/tcp
68
osmo-gtp-hub            4253/tcp
69
osmo-msc                4254/tcp
70
osmo-sip-connector      4256/tcp
71
osmo-hlr                4258/tcp
72
osmo-ggsn               4260/tcp
73
</pre>
74
75
to the end of your @/etc/services@ file.  This will allow you to do something like @telnet localhost osmo-bsc@ rather than having to remember that the number was 4242.
Add picture from clipboard (Maximum size: 48.8 MB)