== Hardware interface ==
2
3
We are using a 120 Ohms balanced connection between the BS11 and a HFC-E1 card.
4
To configure the BS11 hardware correctly, you need to
5
 * open the connection between pin 2 and 3 of the 4 jumpers below connector J01
6
7
=== Cable to RJ45 ===
8
9 3 laforge
 * left Y01 PCM in (from BSC): RJ45 pin 4,5
10
 * Y02 PCM out (to BSC): RJ45 pin 1,2
11
 * Y03 PCM connected 1:1 with Y04 PCM
12 2 laforge
13 1 laforge
== Configuration of BTSM Object ==
14
15
 * BS11 requires PCM30CRC4  64kBit/s no Subslots
16
 * OM Layer on Timeslot 1
17
 * TEI for OM Layer default Siemens is 25 (but configurable in BS11 [wiki:LMT])
18
19
 * the following parameters are not configurable
20
  * RSL Layer on Timeslot 1, too
21
  * TEI for RSL is fixed in  Siemens equipment
22
  * TEI = 0 für TRX0
23
  * TEI = 1 für TRX1
24
  * Attention: if you select OM Layer TEI 0 oder 1, RSL can no longer be brought up
25
26
 * Timeslots for TCHs
27
  * TRX0: TS2 und TS3
28
  * TRX1: TS4 und TS5
29
30
== E1 interface ==
31 2 laforge
32 1 laforge
LI Objekt:  Line  MULTIDROP
33 4 laforge
34 1 laforge
Impedance 120 Ohm balanced to connect to HFC-E1 board
35
Additionally you will need to change some jumpers on the connector board
36 4 laforge
of BS11:
37 5 laforge
 * dip-switch SW3:
38
  * 1-4: off
39
  * 5-8: on
40
 * TB01: no jumper
41
 * TB02: no jumper
42
 * TB03: no jumper
43
 * TB04: no jumper
44 4 laforge
45
SW3 is the dip-switch underneath the connector board
46
TB0* are the four jumpers on the left hand side of the connector board.
47 1 laforge
48
== Database ==
49 2 laforge
50 1 laforge
Important database settings:
51
52
 * the database has to be downloaded from PC via E1 to BS11
53
54
55
 * BCCH channel combination Type  5  oder 8 (including SDCCH for SMS)
56
 * TCH combination 0 oder 9
57
{{{
58
Cell config:    Not hopping
59
                No Concentric Cell = 0
60
                Radiomeasgran =254
61
                No Power Reduction = 0
62
                Excessive distance =0 disabled