BS11Configuration » History » Version 3

laforge, 02/19/2016 10:47 PM

1 2 laforge
== Hardware interface ==
2
3
We are using a 120 Ohms balanced connection between the BS11 and a HFC-E1 card.
4
To configure the BS11 hardware correctly, you need to
5
 * open the connection between pin 2 and 3 of the 4 jumpers below connector J01
6
7
=== Cable to RJ45 ===
8
9 3 laforge
 * left Y01 PCM in (from BSC): RJ45 pin 4,5
10
 * Y02 PCM out (to BSC): RJ45 pin 1,2
11
 * Y03 PCM connected 1:1 with Y04 PCM
12 2 laforge
13 1 laforge
== Configuration of BTSM Object ==
14
15
 * BS11 requires PCM30CRC4  64kBit/s no Subslots
16
 * OM Layer on Timeslot 1
17
 * TEI for OM Layer default Siemens is 25 (but configurable in BS11 [wiki:LMT])
18
19
 * the following parameters are not configurable
20
  * RSL Layer on Timeslot 1, too
21
  * TEI for RSL is fixed in  Siemens equipment
22
  * TEI = 0 für TRX0
23
  * TEI = 1 für TRX1
24
  * Attention: if you select OM Layer TEI 0 oder 1, RSL can no longer be brought up
25
26
 * Timeslots for TCHs
27
  * TRX0: TS2 und TS3
28
  * TRX1: TS4 und TS5
29
30
== E1 interface ==
31 2 laforge
32 1 laforge
LI Objekt:  Line  MULTIDROP
33
Impedance 120 Ohm balanced to connect to HFC-E1 board
34
Additionally you will need to change some jumpers on the connector board
35
of BS11 (FIXME: which ones?)
36
37
== Database ==
38 2 laforge
39 1 laforge
Important database settings:
40
41
 * the database has to be downloaded from PC via E1 to BS11
42
43
44
 * BCCH channel combination Type  5  oder 8 (including SDCCH for SMS)
45
 * TCH combination 0 oder 9
46
{{{
47
Cell config:    Not hopping
48
                No Concentric Cell = 0
49
                Radiomeasgran =254
50
                No Power Reduction = 0
51
                Excessive distance =0 disabled