1 1 laforge
== Configuration of BTSM Object ==
2
3
 * BS11 requires PCM30CRC4  64kBit/s no Subslots
4
 * OM Layer on Timeslot 1
5
 * TEI for OM Layer default Siemens is 25 (but configurable in BS11 [wiki:LMT])
6
7
 * the following parameters are not configurable
8
  * RSL Layer on Timeslot 1, too
9
  * TEI for RSL is fixed in  Siemens equipment
10
  * TEI = 0 für TRX0
11
  * TEI = 1 für TRX1
12
  * Attention: if you select OM Layer TEI 0 oder 1, RSL can no longer be brought up
13
14
 * Timeslots for TCHs
15
  * TRX0: TS2 und TS3
16
  * TRX1: TS4 und TS5
17
18
== E1 interface ==
19
LI Objekt:  Line  MULTIDROP
20
Impedance 120 Ohm balanced to connect to HFC-E1 board
21
Additionally you will need to change some jumpers on the connector board
22
of BS11 (FIXME: which ones?)
23
24
== Database ==
25
Important database settings:
26
27
 * the database has to be downloaded from PC via E1 to BS11
28
29
30
 * BCCH channel combination Type  5  oder 8 (including SDCCH for SMS)
31
 * TCH combination 0 oder 9
32
{{{
33
Cell config:    Not hopping
34
                No Concentric Cell = 0
35
                Radiomeasgran =254
36
                No Power Reduction = 0
37
                Excessive distance =0 disabled
38
}}}