Bug #3271
closed
- Status changed from New to In Progress
- File PULSE_T1094NL.lbr added
- Status changed from In Progress to Resolved
- % Done changed from 0 to 100
repaired PULSE_T1094NL footprint and symbol (solves OSM#3270)
... and OSM#3271. - The transformer symbol is made of two identical coils and hence it is not possible to mark the "2:" side (pins 9-11) separately. But the naming of this coil was changed in a way, that, when invoked, the "2" of the subpart name "TR1-1:2" shows towards the pins 9-11. Maybe we should evolve to a device symbol with two coils merged rather than two identical but separated, then an individual naming could honour the 2:1 side and can not be disturbed by e.g. subsequent mirroring. - Also repaired the name and value designators' layer association.
lib attached to ticket and will be updated in repo next week.
Hi Martin,
thanks for your updates.
On Fri, May 18, 2018 at 08:04:27PM +0000, mschramm [REDMINE] wrote:
lib attached to ticket and will be updated in repo next week.
you now have push access to osmo-e1-xcvr.git, so it can be fixed there, too.
mschramm wrote:
lib attached to ticket and will be updated in repo next week.
done
had to touch this again:
commit 8ce574846d1f18d71b22fa811ebff4fd10694cf8
Author: Martin Schramm <mschramm@sysmocom.de>
Date: Tue May 29 19:21:38 2018 +0200
laforge.lbr: PULSE_T1094NL: better tPlace and tDocu layer (for OSM#3270)
- File deleted (
PULSE_T1094NL.lbr)
(updated discrete Pulse lib here too besides having this implicit in the laforge.lbr and in project's design files)
Also available in: Atom
PDF