Project

General

Profile

Livingston PortMaster 3 » History » Version 19

DrDeke, 11/12/2023 01:29 PM
Fix PM3-CMP photo

1 1 laforge
h1. Livingston Portmaster 3
2 2 laforge
3 15 laforge
@laforge bought three Livingston Portmaster 3 PM3A-1E, which are RAS (Remote Access Server) that
4 2 laforge
* terminates one 1E line (30 B-channels)
5
* provides ISDN dial-up on those channels
6
* provides DSP based modems in case analog modem calls should be handled.
7
8 15 laforge
One unit (rbbs-pm3) is part of the [[retro-bbs:Dialup_Network_In_A_Box]], another unit (pm3-2) is part of the [[octoi:Colocated_Hub]], the third one is at @laforge's basement.
9 3 laforge
10
h2. Documentation
11
12
* attachment:portmaster3_hardware_installation.pdf
13
* attachment:portmaster3_configuration.pdf
14 4 laforge
* more below (Attachments)
15 6 laforge
16 12 laforge
h2. Electronics / Pictures
17
18 13 laforge
h3. External pictures
19
20 1 laforge
{{thumbnail(Livingston_Portmaster3_front.jpg)}}
21
{{thumbnail(Livingston_Portmaster3_top.jpg)}}
22 13 laforge
{{thumbnail(Livingston_Portmaster3_back.jpg)}}
23
24
h3. Mainboard
25
26
{{thumbnail(Livingston_Portmaster3_mainboard.jpg)}}
27
{{thumbnail(Livingston_Portmaster3_mainboard2.jpg)}}
28
{{thumbnail(Livingston_Portmaster3_mainboard_top.jpg)}}
29
{{thumbnail(Livingston_Portmaster3_mainboard_bottom.jpg)}}
30
31
h3. DSP / Modem Board
32
33
There are 6 slots for modem boards, each board typically has 10 soft-modems, resulting in a total capacity of maximum 60 modems (equalling the number of B-channels in 2 E1 PRI links)
34
35
{{thumbnail(Livingston_Portmaster3_dsp_top.jpg)}}
36
{{thumbnail(Livingston_Portmaster3_dsp_bottom.jpg)}}
37 12 laforge
38 18 DrDeke
h3. PM3-CMP Stac Compression Board
39
40
There is a set of expansion headers on the mainboard which, according to the hardware installation guide, can accommodate a "compression or accelerator card". The compression card is model PM3-CMP and allows Stac compression to run on up to 60 channels.
41
42 19 DrDeke
{{thumbnail(pm3-cmp-1.jpg)}}
43 18 DrDeke
44
45 6 laforge
h2. Spare Parts / Mods
46
47
h3. Fan
48
49 7 laforge
The original fan is a Fonsan DFB0812M (DC 12V 0.1A) fan by DELTA ELECTRONICS INC. The specs seem to state 2600 RPM / 24.8 dB(A) / 29 cfm.
50 6 laforge
51
I found it too noisy and replaced it with a Noctua NF-A8 FLX with L.N.A (reduced to 1650 rpm / 12.9 dB(A) / 24 cfm)
52
53 1 laforge
Fun fact: The PM3 actually seems to have a 5V -> 12V DC/DC upconverter just for the fan - instead of simply using a 5V fan...
54 7 laforge
55
h3. Power Supply
56
57 16 laforge
One of the PM3A-E1 at @laforge had a broken power supply.  The oroginal PSU is an ASTEC LPS1112 rated for 5V/22A output (80W convection cooled, 1120W with 30cfm forced air).
58 7 laforge
59 17 laforge
It was replaced with a Mean Well LRS-150F-5. Mechanical assembly via a custom adapter plate that was fabricated easily from a small piece of aluminium sheet metal (175 x 102 mm) with a few drill holes.
60 7 laforge
61
{{thumbnail(PM3-PSU-1.jpg)}}
62 8 laforge
{{thumbnail(PM3-PSU-4.jpg)}}
63
{{thumbnail(PM3-PSU-2.jpg)}}
64 10 laforge
65 14 laforge
h3. Serial console cable
66
67
A null-modem cable can be built with the following pin-out:
68
69
|_.DB-9 female (PC)|_.DB-25 male (PM3)|_.Suggested RJ45|
70
|1|20|1|
71
|2|2|2|
72
|3|3|3|
73
|4|8|4|
74
|5|7|5|
75
|6|-|-|
76
|7|5|6|
77
|8|4|7|
78
|9|22|8|
79
80 10 laforge
h2. Configuration
81
82
h3. route to different telpnet hosts based on called party number
83
84
Assuming one wants to use a PM3 to act as modem bamk for accessing differnt [virtualized] BBSs over telnet, the problem is how to  route the inbound call to a specific telnet IP address.  The non-radius stand-alone configuration of the PM3 only permits either:
85
* automatic forwarding of all calls to one global telnet/rlogin host
86
* allowing the users to enter the hostname for telnet themselves
87 11 laforge
* providing a list of pre-configured telnet desinations to all users (this was used at the 36C3 retronetowrking installation, see [[retro-bbs:36C3]])
88 1 laforge
89 11 laforge
90 10 laforge
However, with the _Call-Check_ radius feature, it should be possibl to receive the called + calling identity before the call is even accepted, and the nin return provide the telnet IP/port to which the call shall be routed.
91
92
Details in
93
* Page 4-17 of the PM3A Radius for Unix manual
94
** PM3A sends _access-request_ with
95
*** User-Name=SETUP.Calling-Station-Id/No-Call-ID
96
*** Service-Type=Call-Check
97
*** Called-Station-Id=SETUP.Called-Station-Id
98
** Radius sends response with
99
*** Login-IP-Host pointing to IP of telnet/rlogin
100
*** Login-Service=(Telnet,Rlogin,TCP-Clear)
101
*** Login-TCP-Port pointing to IP of telnet/rlogin
102 1 laforge
*** Service-Type=Login-User
103 10 laforge
* Page 3-4 of the PortMaster Command Line Reference
104 11 laforge
** @set call-check on@
Add picture from clipboard (Maximum size: 48.8 MB)