Description

If I use the parse tool from my CCID driver to get the supported clock frequencies list I get:
https://ccid.apdu.fr/#CCID_compliant

  bNumClockSupported: 4
   IFD does not support GET CLOCK FREQUENCIES request: LIBUSB_ERROR_TIMEOUT

The CCID specification indicates in 5.3.2 GET_CLOCK_FREQUENCIES:

A CCID with bNumClockSupported equal to 00h does not have to support this request.

Here the sysmoOCTSIM reports bNumClockSupported: 4 so the reader should be able to send the 4 supported clock frequencies.

This issue is somewhat similar to https://osmocom.org/issues/4777
It is not mandatory to fix this since my CCID driver does not use (yet) the clock frequency list.

Actions #1

Updated by rousseau over 2 years ago

I am using the latest firmware 0.2.67-30c2

Actions #2

Updated by laforge over 2 years ago

  • Assignee set to Hoernchen
  • Priority changed from Normal to Low
Actions #3

Updated by rousseau over 2 years ago

  • Parent task set to #4776

This is a duplicate of https://osmocom.org/issues/4776