Actions
Bug #2914
closedOsmoMSC performs RESET procedure even after RESET from BSC
Start date:
02/08/2018
Due date:
% Done:
100%
Resolution:
Spec Reference:
Description
When starting the BSC the first time, the BSC will perform a RESET to the MSC, which the MSC will acknowledge.
For some reason, the MSC itself then sends a RESET to the BSC. Why does it do that? The MSC has not lost any state.
To make things worse, the behavior changes for subsequent restarts of the BSC. Suddenly, the MSC does not return with a RESET procedure after the BSC performs RESET.
Updated by laforge about 6 years ago
- Status changed from New to In Progress
- Assignee changed from 4368 to laforge
Updated by laforge about 6 years ago
- Status changed from In Progress to Resolved
- % Done changed from 0 to 100
Ie67e7ed20a6c42afe99bafef96d85a4e083dd057 was merged
Actions