GAP NWK Feature N.15 - Alerting¶
Feature definition¶
alerting N15: activates or deactivates alerting at the PP using any appropriate indication.
Feature to procedure mapping¶
Procedure | Reference | PT | FT R/B | FT P | Status |
PT alerting | 8.14 | M | M | M | All |
The PT alerting procedure is supported by libnl. The <<SIGNAL>> IE can be placed
in either the {CC-SETUP} or a {CC-INFO} message.