openDUG can come up, but with Avail: "Power Off"
Start date:
05/24/2022
Due date:
% Done:
0%
Spec Reference:
Description
Sometimes, after starting osmo-bsc, The BTS will transmit, we even start to get Channel requests, but this is the status:
OsmoBSC# show trx TRX 0 of BTS 0 is on ARFCN 251 RF Nominal Power: 37 dBm, reduced by 0 dB, resulting BS power: 37 dBm Radio Carrier NM State: Oper 'NULL', Admin 'Unlocked', Avail 'Power off' RSL State: connected Baseband Transceiver NM State: Oper 'NULL', Admin 'Locked', Avail 'Power off' E1 Signalling Link: E1 Line 0, Type e1d: Timeslot 1, Mode RSL E1 TEI 0, SAPI 0
and of course we get such as this:
DRSL NOTICE <0003> abis_rsl.c:2193 (bts=0) CHAN RQD[Location updating]: no resources for SDCCH 0x4, retrying with TCH_F DRLL DEBUG <0000> lchan_select.c:299 (bts=0) lchan_select_by_type(TCH_F) DRLL DEBUG <0000> lchan_select.c:233 (bts=0) lchan_avail_by_type(TCH_F) DRLL DEBUG <0000> lchan_select.c:65 looking for lchan TCH/F: (bts=0,trx=0) trx not usable DRLL DEBUG <0000> lchan_select.c:65 looking for lchan TCH/F_PDCH as TCH/F without pchan switch: (bts=0,trx=0) trx not usable DRLL DEBUG <0000> lchan_select.c:65 looking for lchan TCH/F_PDCH as TCH/F: (bts=0,trx=0) trx not usable DRLL DEBUG <0000> lchan_select.c:65 looking for lchan TCH/F_TCH/H_SDCCH8_PDCH as TCH/F without pchan switch: (bts=0,trx=0) trx not usable DRLL DEBUG <0000> lchan_select.c:65 looking for lchan TCH/F_TCH/H_SDCCH8_PDCH as TCH/F: (bts=0,trx=0) trx not usable DRLL NOTICE <0000> lchan_select.c:305 (bts=0) Failed to select TCH_F channel
Stopping and restarting osmo-bsc will sooner ( or later :-/ ) get the TRX up....
Attached is osmo-bsc.log of the bring-up and pcap of same.
I suspect there is something happening in a certain order sometimes that causes this?