INFO
Test log initialized.
INFO
User Input module initialized
INFO
Windows 10 Pro (Build 18362.1.amd64fre.19h1_release.190318-1202)
INFO
CVExe.exe ver 3.0.0.0
INFO
BaseUtilities.dll ver 3.0.0.0
INFO
CommandVerifierLog.dll ver 3.0.0.0
INFO
TSMFCGuiDialogHelperDLL.dll ver 3.0.0.0
INFO
TestUtilities.dll ver 3.0.0.0
INFO
TestSuiteEngine.dll ver 3.0.0.0
INFO
VIFReader.dll ver 3.0.0.0
INFO
xhci_DevIOCTL.dll ver 2.1.10.5
INFO
xhci_TestServices.dll ver 2.1.10.5
INFO
USBUtilities.dll ver 1.4.5.1
INFO
StackSwitcher.dll ver 1.4.5.1
INFO
xhci_USBCommandVerifier.dll ver 2.1.10.5
INFO
USB20_USBCommandVerifier.dll ver 2.1.10.5
INFO
Host 1 selected: xHCI Host: VID=0x8086, PID=0x9cb1 (PCI-Bus 0, Gerät 20, Funktion 0)
INFO
DUT selected: FS Device addr=1: VID=1d50, PID=6145
INFO
Topology: XHCI HC -- DUT
INFO
Start time: Tue Feb 1 16:04:10 2022
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x21 (HID Descriptor)
INFO
Number of interface descriptors found 0x6
INFO
Number of alternate interface descriptors found : 0x2
INFO
Number of endpoint descriptors found : 0xD
INFO
Configuration descriptor length : 0x9
INFO
Configuration descriptor type : 0x2
INFO
Configuration descriptor TotalLength : 0xC3
INFO
Configuration descriptor NumInterfaces : 0x6
INFO
Configuration descriptor ConfigurationValue: 0x1
INFO
ENGLISH_US language string descriptor is : Main
INFO
Configuration descriptor bmAttributes : 0x80
INFO
Device does not support remote wake up
INFO
MaxPower = 50 PowerMultiplier = 2
INFO
Maximum power device requires : 100mA
INFO
Device is BUS POWERED
INFO
Stop time: Tue Feb 1 16:04:11 2022
INFO
Stopping Test [ TD 9.2 - Configuration Descriptor Test (Configuration Index 0) - default:
Number of: Fails (0); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:12 2022
INFO
Bandwidth check passed
INFO
Testing Interface number : 0x0 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 0 (disabled)
INFO
Testing Interface number : 0x0 Alternate setting : 0x1
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x1
INFO
Interface descriptor bNumEndPoints: 0x4
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 0
INFO
Testing Interface number : 0x1 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 1 (disabled)
INFO
Testing Interface number : 0x1 Alternate setting : 0x1
ERROR
Interface number 0x3 not in sequential order
FAIL
(1.2.46) Interface numbers must be in sequential order.
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x1
INFO
Interface descriptor bNumEndPoints: 0x4
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 1
INFO
Testing Interface number : 0x3 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0x2
INFO
Interface class code indicates [CDC-Control] Interface
INFO
Interface sub class : 2 <not defined>
INFO
Interface protocol : 0 <not defined>
INFO
Interface descriptor bInterfaceSubClass : 0x2
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : GPS (CDC control)
INFO
Testing Interface number : 0x4 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x2
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0xA
INFO
Interface class code indicates [CDC-Data] Interface
INFO
Interface sub class : 0 <not defined>
INFO
Interface protocol : 0 <not defined>
INFO
Interface descriptor bInterfaceSubClass : 0x0
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : GPS (CDC data)
INFO
Testing Interface number : 0x5 Alternate setting : 0x0
ERROR
Interface number 0x2 not in sequential order
FAIL
(1.2.46) Interface numbers must be in sequential order.
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x0
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Interface descriptor bInterfaceProtocol assigned by the USB-IF : 0xD0
INFO
ENGLISH_US language string descriptor is : GPS-DO control
INFO
Testing Interface number : 0x2 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x0
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0xFE
INFO
Interface class code indicates [Application-Specific] Interface
INFO
Interface sub class : 1 (Device Firmware Upgrade)
INFO
Interface protocol : 1 (Runtime protocol)
INFO
Interface descriptor bInterfaceSubClass : 0x1
INFO
Interface descriptor bInterfaceProtocol assigned by the USB-IF : 0x1
INFO
ENGLISH_US language string descriptor is : DFU runtime
INFO
Stop time: Tue Feb 1 16:04:13 2022
INFO
Stopping Test [ TD 9.4 - Interface Descriptor Test (Configuration Index 0) - default:
Number of: Fails (2); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:13 2022
INFO
Testing Interface number : 0x0 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x3, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x0 Alternate setting : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x2, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x1, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x1, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x11
INFO
Endpoint descriptor raw MaxPacketSize : 0x3
INFO
Endpoint descriptor interval : 0x3
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x3, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x1 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x6, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x1 Alternate setting : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x5, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x4, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x4, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x11
INFO
Endpoint descriptor raw MaxPacketSize : 0x3
INFO
Endpoint descriptor interval : 0x3
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x6, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x3 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x8, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x40
INFO
Testing Interface number : 0x4 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Bulk, Number : 0x9, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x2
INFO
Endpoint descriptor raw MaxPacketSize : 0x40
INFO
Endpoint descriptor interval : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Bulk, Number : 0x9, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x2
INFO
Endpoint descriptor raw MaxPacketSize : 0x40
INFO
Endpoint descriptor interval : 0x0
INFO
Testing Interface number : 0x5 Alternate setting : 0x0
INFO
Testing Interface number : 0x2 Alternate setting : 0x0
INFO
Stop time: Tue Feb 1 16:04:14 2022
INFO
Stopping Test [ TD 9.5 - Endpoint Descriptor Test (Configuration Index 0) - default:
Number of: Fails (0); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:17 2022
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x21 (HID Descriptor)
INFO
Number of interface descriptors found 0x6
INFO
Number of alternate interface descriptors found : 0x2
INFO
Number of endpoint descriptors found : 0xD
INFO
Configuration descriptor length : 0x9
INFO
Configuration descriptor type : 0x2
INFO
Configuration descriptor TotalLength : 0xC3
INFO
Configuration descriptor NumInterfaces : 0x6
INFO
Configuration descriptor ConfigurationValue: 0x1
INFO
ENGLISH_US language string descriptor is : Main
INFO
Configuration descriptor bmAttributes : 0x80
INFO
Device does not support remote wake up
INFO
MaxPower = 50 PowerMultiplier = 2
INFO
Maximum power device requires : 100mA
INFO
Device is BUS POWERED
INFO
Stop time: Tue Feb 1 16:04:18 2022
INFO
Stopping Test [ TD 9.2 - Configuration Descriptor Test (Configuration Index 0) - addressed:
Number of: Fails (0); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:19 2022
INFO
Bandwidth check passed
INFO
Testing Interface number : 0x0 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 0 (disabled)
INFO
Testing Interface number : 0x0 Alternate setting : 0x1
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x1
INFO
Interface descriptor bNumEndPoints: 0x4
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 0
INFO
Testing Interface number : 0x1 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 1 (disabled)
INFO
Testing Interface number : 0x1 Alternate setting : 0x1
ERROR
Interface number 0x3 not in sequential order
FAIL
(1.2.46) Interface numbers must be in sequential order.
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x1
INFO
Interface descriptor bNumEndPoints: 0x4
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 1
INFO
Testing Interface number : 0x3 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0x2
INFO
Interface class code indicates [CDC-Control] Interface
INFO
Interface sub class : 2 <not defined>
INFO
Interface protocol : 0 <not defined>
INFO
Interface descriptor bInterfaceSubClass : 0x2
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : GPS (CDC control)
INFO
Testing Interface number : 0x4 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x2
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0xA
INFO
Interface class code indicates [CDC-Data] Interface
INFO
Interface sub class : 0 <not defined>
INFO
Interface protocol : 0 <not defined>
INFO
Interface descriptor bInterfaceSubClass : 0x0
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : GPS (CDC data)
INFO
Testing Interface number : 0x5 Alternate setting : 0x0
ERROR
Interface number 0x2 not in sequential order
FAIL
(1.2.46) Interface numbers must be in sequential order.
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x0
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Interface descriptor bInterfaceProtocol assigned by the USB-IF : 0xD0
INFO
ENGLISH_US language string descriptor is : GPS-DO control
INFO
Testing Interface number : 0x2 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x0
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0xFE
INFO
Interface class code indicates [Application-Specific] Interface
INFO
Interface sub class : 1 (Device Firmware Upgrade)
INFO
Interface protocol : 1 (Runtime protocol)
INFO
Interface descriptor bInterfaceSubClass : 0x1
INFO
Interface descriptor bInterfaceProtocol assigned by the USB-IF : 0x1
INFO
ENGLISH_US language string descriptor is : DFU runtime
INFO
Stop time: Tue Feb 1 16:04:20 2022
INFO
Stopping Test [ TD 9.4 - Interface Descriptor Test (Configuration Index 0) - addressed:
Number of: Fails (2); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:20 2022
INFO
Testing Interface number : 0x0 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x3, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x0 Alternate setting : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x2, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x1, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x1, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x11
INFO
Endpoint descriptor raw MaxPacketSize : 0x3
INFO
Endpoint descriptor interval : 0x3
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x3, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x1 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x6, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x1 Alternate setting : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x5, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x4, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x4, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x11
INFO
Endpoint descriptor raw MaxPacketSize : 0x3
INFO
Endpoint descriptor interval : 0x3
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x6, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x3 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x8, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x40
INFO
Testing Interface number : 0x4 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Bulk, Number : 0x9, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x2
INFO
Endpoint descriptor raw MaxPacketSize : 0x40
INFO
Endpoint descriptor interval : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Bulk, Number : 0x9, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x2
INFO
Endpoint descriptor raw MaxPacketSize : 0x40
INFO
Endpoint descriptor interval : 0x0
INFO
Testing Interface number : 0x5 Alternate setting : 0x0
INFO
Testing Interface number : 0x2 Alternate setting : 0x0
INFO
Stop time: Tue Feb 1 16:04:21 2022
INFO
Stopping Test [ TD 9.5 - Endpoint Descriptor Test (Configuration Index 0) - addressed:
Number of: Fails (0); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:23 2022
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x24
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x5 (Endpoint Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x4 (Interface Descriptor)
INFO
Configuration descriptor contains descriptor of type : 0x21 (HID Descriptor)
INFO
Number of interface descriptors found 0x6
INFO
Number of alternate interface descriptors found : 0x2
INFO
Number of endpoint descriptors found : 0xD
INFO
Configuration descriptor length : 0x9
INFO
Configuration descriptor type : 0x2
INFO
Configuration descriptor TotalLength : 0xC3
INFO
Configuration descriptor NumInterfaces : 0x6
INFO
Configuration descriptor ConfigurationValue: 0x1
INFO
ENGLISH_US language string descriptor is : Main
INFO
Configuration descriptor bmAttributes : 0x80
INFO
Device does not support remote wake up
INFO
MaxPower = 50 PowerMultiplier = 2
INFO
Maximum power device requires : 100mA
INFO
Device is BUS POWERED
INFO
Device is currently BUS POWERED
INFO
Currently remote wakeup is DISABLED
INFO
Stop time: Tue Feb 1 16:04:24 2022
INFO
Stopping Test [ TD 9.2 - Configuration Descriptor Test (Configuration Index 0) - configured:
Number of: Fails (0); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:25 2022
INFO
Bandwidth check passed
INFO
Testing Interface number : 0x0 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 0 (disabled)
INFO
Testing Interface number : 0x0 Alternate setting : 0x1
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x1
INFO
Interface descriptor bNumEndPoints: 0x4
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 0
INFO
Testing Interface number : 0x1 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 1 (disabled)
INFO
Testing Interface number : 0x1 Alternate setting : 0x1
ERROR
Interface number 0x3 not in sequential order
FAIL
(1.2.46) Interface numbers must be in sequential order.
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x1
INFO
Interface descriptor bNumEndPoints: 0x4
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : E1 port 1
INFO
Testing Interface number : 0x3 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x1
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0x2
INFO
Interface class code indicates [CDC-Control] Interface
INFO
Interface sub class : 2 <not defined>
INFO
Interface protocol : 0 <not defined>
INFO
Interface descriptor bInterfaceSubClass : 0x2
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : GPS (CDC control)
WARNING
SetInterface with interface number : 0x3 failed.
INFO
Testing Interface number : 0x4 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x2
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0xA
INFO
Interface class code indicates [CDC-Data] Interface
INFO
Interface sub class : 0 <not defined>
INFO
Interface protocol : 0 <not defined>
INFO
Interface descriptor bInterfaceSubClass : 0x0
INFO
Device does not use a class-specific protocol on this interface
INFO
ENGLISH_US language string descriptor is : GPS (CDC data)
WARNING
SetInterface with interface number : 0x4 failed.
INFO
Testing Interface number : 0x5 Alternate setting : 0x0
ERROR
Interface number 0x2 not in sequential order
FAIL
(1.2.46) Interface numbers must be in sequential order.
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x0
INFO
Interface descriptor bInterfaceClass is vendor-specific
INFO
Interface descriptor bInterfaceSubClass : 0xE1
INFO
Interface descriptor bInterfaceProtocol assigned by the USB-IF : 0xD0
INFO
ENGLISH_US language string descriptor is : GPS-DO control
WARNING
SetInterface with interface number : 0x5 failed.
INFO
Testing Interface number : 0x2 Alternate setting : 0x0
INFO
Interface descriptor length : 0x9
INFO
Interface descriptor bDescriptorType : 0x4
INFO
Interface descriptor bAlternateSetting : 0x0
INFO
Interface descriptor bNumEndPoints: 0x0
INFO
Interface descriptor bInterfaceClass reserved for assignment by the USB-IF : 0xFE
INFO
Interface class code indicates [Application-Specific] Interface
INFO
Interface sub class : 1 (Device Firmware Upgrade)
INFO
Interface protocol : 1 (Runtime protocol)
INFO
Interface descriptor bInterfaceSubClass : 0x1
INFO
Interface descriptor bInterfaceProtocol assigned by the USB-IF : 0x1
INFO
ENGLISH_US language string descriptor is : DFU runtime
INFO
Stop time: Tue Feb 1 16:04:26 2022
INFO
Stopping Test [ TD 9.4 - Interface Descriptor Test (Configuration Index 0) - configured:
Number of: Fails (2); Aborts (0); Warnings (3) ]
INFO
Start time: Tue Feb 1 16:04:26 2022
INFO
Testing Interface number : 0x0 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x3, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x0 Alternate setting : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x2, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x1, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x1, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x11
INFO
Endpoint descriptor raw MaxPacketSize : 0x3
INFO
Endpoint descriptor interval : 0x3
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x3, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x1 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x6, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x1 Alternate setting : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x5, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x4, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x5
INFO
Endpoint descriptor raw MaxPacketSize : 0x124
INFO
Endpoint descriptor interval : 0x1
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Isochronous, Number : 0x4, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x11
INFO
Endpoint descriptor raw MaxPacketSize : 0x3
INFO
Endpoint descriptor interval : 0x3
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x6, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x4
INFO
Testing Interface number : 0x3 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Interrupt, Number : 0x8, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x3
INFO
Endpoint descriptor raw MaxPacketSize : 0xA
INFO
Endpoint descriptor interval : 0x40
INFO
Testing Interface number : 0x4 Alternate setting : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Bulk, Number : 0x9, Direction : OUT
INFO
Endpoint descriptor bmAttributes : 0x2
INFO
Endpoint descriptor raw MaxPacketSize : 0x40
INFO
Endpoint descriptor interval : 0x0
INFO
Endpoint descriptor length : 0x7
INFO
Endpoint descriptor type : 0x5
INFO
Endpoint Type : Bulk, Number : 0x9, Direction : IN
INFO
Endpoint descriptor bmAttributes : 0x2
INFO
Endpoint descriptor raw MaxPacketSize : 0x40
INFO
Endpoint descriptor interval : 0x0
INFO
Testing Interface number : 0x5 Alternate setting : 0x0
INFO
Testing Interface number : 0x2 Alternate setting : 0x0
INFO
Stop time: Tue Feb 1 16:04:27 2022
INFO
Stopping Test [ TD 9.5 - Endpoint Descriptor Test (Configuration Index 0) - configured:
Number of: Fails (0); Aborts (0); Warnings (0) ]
INFO
Start time: Tue Feb 1 16:04:28 2022
INFO
Testing Interface number : 0x0 Alternate setting : 0x0
INFO
Testing EndPoint type : Interrupt, Address : 0x83
INFO
Endpoint is currently not halted for endpoint 0x83
INFO
Setting feature endpoint halt for endpoint 0x83
INFO
Endpoint is halted for endpoint 0x83
INFO
Clearing feature endpoint halt for endpoint 0x83
INFO
Endpoint is no longer halted for endpoint 0x83
INFO
Testing Interface number : 0x0 Alternate setting : 0x1
INFO
Testing EndPoint type : Isochronous, Address : 0x82
INFO
Control/Isochronous endpoint. HaltEndpoint Test skipped
INFO
Testing EndPoint type : Isochronous, Address : 0x1
INFO
Control/Isochronous endpoint. HaltEndpoint Test skipped
INFO
Testing EndPoint type : Isochronous, Address : 0x81
INFO
Control/Isochronous endpoint. HaltEndpoint Test skipped
INFO
Testing EndPoint type : Interrupt, Address : 0x83
INFO
Endpoint is currently not halted for endpoint 0x83
INFO
Setting feature endpoint halt for endpoint 0x83
INFO
Endpoint is halted for endpoint 0x83
INFO
Clearing feature endpoint halt for endpoint 0x83
INFO
Endpoint is no longer halted for endpoint 0x83
INFO
Testing Interface number : 0x1 Alternate setting : 0x0
INFO
Testing EndPoint type : Interrupt, Address : 0x86
INFO
Endpoint is currently not halted for endpoint 0x86
INFO
Setting feature endpoint halt for endpoint 0x86
INFO
Endpoint is halted for endpoint 0x86
INFO
Clearing feature endpoint halt for endpoint 0x86
INFO
Endpoint is no longer halted for endpoint 0x86
INFO
Testing Interface number : 0x1 Alternate setting : 0x1
INFO
Testing EndPoint type : Isochronous, Address : 0x85
INFO
Control/Isochronous endpoint. HaltEndpoint Test skipped
INFO
Testing EndPoint type : Isochronous, Address : 0x4
INFO
Control/Isochronous endpoint. HaltEndpoint Test skipped
INFO
Testing EndPoint type : Isochronous, Address : 0x84
INFO
Control/Isochronous endpoint. HaltEndpoint Test skipped
INFO
Testing EndPoint type : Interrupt, Address : 0x86
INFO
Endpoint is currently not halted for endpoint 0x86
INFO
Setting feature endpoint halt for endpoint 0x86
INFO
Endpoint is halted for endpoint 0x86
INFO
Clearing feature endpoint halt for endpoint 0x86
INFO
Endpoint is no longer halted for endpoint 0x86
INFO
Testing Interface number : 0x3 Alternate setting : 0x0
WARNING
SetInterface with interface number : 0x3 failed.
INFO
Testing EndPoint type : Interrupt, Address : 0x88
INFO
Endpoint is currently not halted for endpoint 0x88
INFO
Setting feature endpoint halt for endpoint 0x88
INFO
Endpoint is halted for endpoint 0x88
INFO
Clearing feature endpoint halt for endpoint 0x88
INFO
Endpoint is no longer halted for endpoint 0x88
INFO
Testing Interface number : 0x4 Alternate setting : 0x0
WARNING
SetInterface with interface number : 0x4 failed.
INFO
Testing EndPoint type : Bulk, Address : 0x9
INFO
Endpoint is currently not halted for endpoint 0x09
INFO
Setting feature endpoint halt for endpoint 0x09
INFO
Endpoint is halted for endpoint 0x09
INFO
Clearing feature endpoint halt for endpoint 0x09
INFO
Endpoint is no longer halted for endpoint 0x09
INFO
Testing EndPoint type : Bulk, Address : 0x89
INFO
Endpoint is currently not halted for endpoint 0x89
INFO
Setting feature endpoint halt for endpoint 0x89
INFO
Endpoint is halted for endpoint 0x89
INFO
Clearing feature endpoint halt for endpoint 0x89
INFO
Endpoint is no longer halted for endpoint 0x89
INFO
Testing Interface number : 0x5 Alternate setting : 0x0
WARNING
SetInterface with interface number : 0x5 failed.
INFO
Testing Interface number : 0x2 Alternate setting : 0x0
INFO
Stop time: Tue Feb 1 16:04:29 2022
INFO
Stopping Test [ TD 9.9 - Halt Endpoint Test (Configuration Index 0):