Project

General

Profile

Actions

Bug #4643

closed

OM2K: 'MO object should not generate any message'

Added by laforge over 3 years ago. Updated about 2 years ago.

Status:
Resolved
Priority:
Normal
Assignee:
Category:
Ericsson BTS
Target version:
-
Start date:
07/03/2020
Due date:
% Done:

100%

Spec Reference:

Description

<0005> abis_om2000.c:2631 Rx MO=CF/00/ff/00 Fault Report (80 80 00 2c 00 42 0a 00 ff 00 23 02 00 02 00 00 00 24 00 00 00 00 00 00 25 00 00 80 00 00 00 14 00 00 15 00 00 34 00 80 00 00 00 00 2c 00 2a 00 )
<0005> abis_om2000.c:2457 Rx MO=CF/00/ff/00 Fault Report, MO State: RESET
<0005> abis_om2000.c:2506 Rx MO=CF/00/ff/00 Fault Report: Internal Fault Map Class 1A (1,17)
<0005> abis_om2000.c:2506 Rx MO=CF/00/ff/00 Fault Report: Internal Fault Map Class 2A (23)
<0005> abis_om2000.c:2506 Rx MO=CF/00/ff/00 Fault Report: Replacement Unit Map (15)
<0005> abis_om2000.c:1019 Tx MO=CF/00/ff/00 Fault Report ACK
<0005> abis_om2000.c:2713 MO object should not generate any message. fsm == NULL Fault Report: [L2]> 80 80 00 2c 00 42 0a 00 ff 00 [L3]> 23 02 00 02 00 00 00 24 00 00 00 00 00 00 25 00 00 80 00 00 00 14 00 00 15 00 00 34 00 80 00 00 00 00 2c 00 2a 00 

Related issues

Related to OsmoBSC - Bug #4670: CF / Calendar Time Request: MO object should not generate any messageResolvedlaforge07/19/2020

Actions
Actions #1

Updated by laforge over 3 years ago

  • Project changed from OsmoNITB to OsmoBSC
  • Category set to Ericsson BTS

also appears on osmo-bsc, but at a different MO:

<0017> e1_input.c:746 E1TS(0:1) RX: 80 80 00 06 00 12 0a 00 ff 00  sapi=62 tei=62
<0004> abis_om2000.c:2898 Rx MO=CF/00/ff/00 Calendar Time Request (80 80 00 06 00 12 0a 00 ff 00 )
<0004> abis_om2000.c:2990 MO object should not generate any message. fsm == NULL Calendar Time Request: [L2]> 80 80 00 06 00 12 0a 00 ff 00 [L3]> 
<0017> input/dahdi.c:263 E1TS(0:1) TX: 80 80 00 0d 00 10 0a 00 ff 00 0d 14 07 03 14 08 36 

Actions #2

Updated by laforge over 3 years ago

<0004> bts_ericsson_rbs2000.c:125 inp_sig_cb(): Input signal 'TEI-UP' received
<0004> bts_ericsson_rbs2000.c:54 bootstrapping OML for TRX 0/0
Getting attributes from BTS0 type rbs2000 is not supported.
Getting attributes from BTS0 type rbs2000 is not supported.
<0004> abis_om2000.c:2898 Rx MO=TRXC/00/ff/00 Fault Report (80 80 00 2c 00 42 01 00 ff 00 23 02 00 00 00 00 00 24 00 00 00 00 00 00 25 00 00 00 00 00 00 14 00 00 15 00 00 34 00 00 00 00 00 00 2c 00 2a 00 )
<0004> abis_om2000.c:2724 Rx MO=TRXC/00/ff/00 Fault Report, MO State: RESET
<0004> abis_om2000.c:2773 Rx MO=TRXC/00/ff/00 Fault Report: Internal Fault Map Class 1A (1)
<0004> abis_om2000.c:1114 Tx MO=TRXC/00/ff/00 Fault Report ACK
<0004> abis_om2000.c:2990 MO object should not generate any message. fsm == NULL Fault Report: [L2]> 80 80 00 2c 00 42 01 00 ff 00 [L3]> 23 02 00 00 00 00 00 24 00 00 00 00 00 00 25 00 00 00 00 00 00 14 00 00 15 00 00 34 00 00 00 00 00 00 2c 00 2a 00 
Actions #3

Updated by laforge over 3 years ago

  • Related to Bug #4670: CF / Calendar Time Request: MO object should not generate any message added
Actions #4

Updated by laforge about 2 years ago

  • Status changed from New to Resolved
  • % Done changed from 0 to 100
Actions

Also available in: Atom PDF

Add picture from clipboard (Maximum size: 48.8 MB)