Actions
Bug #4557
opennormal BSSMAP Clear Command from MSC contains cause == 0 meaning "Radio interface message failure"
Status:
New
Priority:
Normal
Assignee:
-
Category:
-
Target version:
-
Start date:
05/20/2020
Due date:
% Done:
0%
Resolution:
Spec Reference:
Description
After a normal Location Updating, the MSC closes the connection to the BSC by sending a Clear Command.
This contains a cause == 0 indicating a failure.
Which cause should it be? maybe no cause IE? Investigate and fix in osmo-msc.
Files
Updated by neels almost 4 years ago
- File clear_command.pcapng clear_command.pcapng added
Updated by neels almost 4 years ago
word has it that Huawei MSC sends Clear with BSSMAP Cause: Call control (0x09) after a successful LU