closed

vty: wrong RF Nominal Power in `show trx 0`

Added by lynxis almost 5 years ago. Updated over 4 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
-
Start date:
05/23/2019
Due date:
% Done:

100%

Spec Reference:

Description

  • connect via vty
  • enable
  • show trx 0
      RF Nominal Power: 23000 dBm, reduced by 20 dB, resulting BS power: 22980 dBm
    

The BS power should be 3000 dbm

Actions #1

Updated by laforge almost 5 years ago

  • Status changed from New to Feedback
  • Assignee set to lynxis
Actions #2

Updated by lynxis over 4 years ago

  • Status changed from Feedback to Closed
  • % Done changed from 0 to 100

it works.