"show trx" doesn't show missing RSL connection

Added by laforge 11 days ago. Updated 7 days ago.

Status:
New
Priority:
Normal
Assignee:
-
Category:
A-bis RSL
Target version:
-
Start date:
12/06/2017
Due date:
% Done:

0%

Spec Reference:

Description

The output of "show trx" looks identical whether or not the RSL connection is established by the TRX:


TRX 0 of BTS 0 is on ARFCN 871
Description: (null)
  RF Nominal Power: 23 dBm, reduced by 20 dB, resulting BS power: 3 dBm
  NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
  Baseband Transceiver NM State: Oper 'Enabled', Admin 'Unlocked', Avail 'OK'
  ip.access stream ID: 0x00

basically, it only shows the OML point of view, and not the RSL point of view.

History

#1 Updated by laforge 7 days ago

  • Project changed from OpenBSC to OsmoBSC
  • Category deleted (libbsc)

#2 Updated by laforge 7 days ago

  • Category set to A-bis RSL

Also available in: Atom PDF