Description

During EGPRS UL testing with osmo-trx setup, it is seen that MCS gets reduced very fast even when radio condition is good. Same issue is present for GPRS testing as well.

This condition exists only with osmo-trx setup.

History

#1 Updated by arvind.sirsikar almost 2 years ago

We have modified osmo-pcu.cfg as below

cs link-quality-ranges cs1 6 cs2 5 8 cs3 7 13 cs4 12

TO

cs link-quality-ranges cs1 0 cs2 0 8 cs3 0 13 cs4 0

and validated in integration setup. further investigation needs to be done on how measurement parameter is conveyed between TRX and PCU apart from the usual DATA-IND message

#2 Updated by arvind.sirsikar almost 2 years ago

  • Status changed from New to Stalled

#3 Updated by laforge about 1 year ago

#4 Updated by laforge about 1 year ago

  • Status changed from Stalled to New
  • Assignee set to sysmocom